eHealth Infrastructure
2.3.0 - release

eHealth Infrastructure - Local Development build (v2.3.0). See the Directory of published versions

: Device Measuring Quality - TTL Representation

Active as of 2019-01-29

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CodeSystem;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "ehealth-device-measuring-quality"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>This code system <code>http://ehealth.sundhed.dk/cs/device-measuring-quality</code> defines the following codes:</p><table class=\"codes\"><tr><td><b>Lvl</b></td><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td>1</td><td style=\"white-space:nowrap\">none<a name=\"ehealth-device-measuring-quality-none\"> </a></td><td>No quality needed</td><td>Quality value where no derivation rule logic nor values are expected</td></tr><tr><td>2</td><td style=\"white-space:nowrap\">  unknown<a name=\"ehealth-device-measuring-quality-unknown\"> </a></td><td>Unknown quality</td><td>Unknown quality (Unlikely to be adequate if a quality value is expected)</td></tr><tr><td>3</td><td style=\"white-space:nowrap\">    derivation-error<a name=\"ehealth-device-measuring-quality-derivation-error\"> </a></td><td>Error in deriving or determining the quality</td><td>Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error</td></tr><tr><td>4</td><td style=\"white-space:nowrap\">      normal<a name=\"ehealth-device-measuring-quality-normal\"> </a></td><td>Normal/neutral device measuring quality</td><td>Normal/neutral device measuring quality</td></tr><tr><td>5</td><td style=\"white-space:nowrap\">        low-precision<a name=\"ehealth-device-measuring-quality-low-precision\"> </a></td><td>Low precision/credibility grade device quality</td><td>Low precision/credibility grade device quality. Typically such device is not clinical grade.</td></tr><tr><td>6</td><td style=\"white-space:nowrap\">          low-precision-degraded<a name=\"ehealth-device-measuring-quality-low-precision-degraded\"> </a></td><td>Degraded quality for low precision/credibility grade device</td><td>Degraded quality for low precision/credibility grade device. Typically such device is not clinical grade.</td></tr><tr><td>7</td><td style=\"white-space:nowrap\">            low-precision-normal<a name=\"ehealth-device-measuring-quality-low-precision-normal\"> </a></td><td>Normal/neutral quality for low precision/credibility grade device</td><td>Normal/neutral quality for low precision/credibility grade device. Typically such device is not clinical grade.</td></tr><tr><td>8</td><td style=\"white-space:nowrap\">              low-precision-uncalibrated<a name=\"ehealth-device-measuring-quality-low-precision-uncalibrated\"> </a></td><td>Quality for uncalibrated low precision/credibility grade device</td><td>Quality for uncalibrated low precision/credibility grade device. Typically such device is not clinical grade.</td></tr><tr><td>9</td><td style=\"white-space:nowrap\">                low-precision-calibrated<a name=\"ehealth-device-measuring-quality-low-precision-calibrated\"> </a></td><td>Quality for calibrated low precision/credibility grade device</td><td>Quality for calibrated low precision/credibility grade device. Typically such device is not clinical grade.</td></tr><tr><td>10</td><td style=\"white-space:nowrap\">                  high-precision<a name=\"ehealth-device-measuring-quality-high-precision\"> </a></td><td>High precision/credibility grade device quality</td><td>High precision/credibility grade device quality. Typically such device is clinical grade.</td></tr><tr><td>11</td><td style=\"white-space:nowrap\">                    high-precision-degraded<a name=\"ehealth-device-measuring-quality-high-precision-degraded\"> </a></td><td>Degraded quality for high precision/credibility grade device</td><td>Degraded quality for high precision/credibility grade device. Typically such device is clinical grade.</td></tr><tr><td>12</td><td style=\"white-space:nowrap\">                      high-precision-normal<a name=\"ehealth-device-measuring-quality-high-precision-normal\"> </a></td><td>Normal/neutral quality for high precision/credibility grade device</td><td>Normal/neutral quality for high precision/credibility grade device. Typically such device is clinical grade.</td></tr><tr><td>13</td><td style=\"white-space:nowrap\">                        high-precision-uncalibrated<a name=\"ehealth-device-measuring-quality-high-precision-uncalibrated\"> </a></td><td>Quality for uncalibrated high precision/credibility grade device</td><td>Quality for uncalibrated high precision/credibility grade device. Typically such device is clinical grade.</td></tr><tr><td>14</td><td style=\"white-space:nowrap\">                          high-precision-calibrated<a name=\"ehealth-device-measuring-quality-high-precision-calibrated\"> </a></td><td>Quality for calibrated high precision/credibility grade device</td><td>Quality for calibrated high precision/credibility grade device. Typically such device is clinical grade.</td></tr><tr><td>1</td><td style=\"white-space:nowrap\">TBD<a name=\"ehealth-device-measuring-quality-TBD\"> </a></td><td>Example value - Under construction</td><td>Example value - Under construction</td></tr></table><p><b>Additional Language Displays</b></p><table class=\"codes\"><tr><td><b>Code</b></td><td><b>Dansk (Danish, da)</b></td></tr><tr><td>none</td><td>Ingen udstyrskvalitet krævet/ventet</td></tr><tr><td>TBD</td><td></td></tr></table></div>"
  ];
  fhir:CodeSystem.url [ fhir:value "http://ehealth.sundhed.dk/cs/device-measuring-quality"];
  fhir:CodeSystem.version [ fhir:value "2.3.0"];
  fhir:CodeSystem.name [ fhir:value "DeviceMeasuringQuality"];
  fhir:CodeSystem.title [ fhir:value "Device Measuring Quality"];
  fhir:CodeSystem.status [ fhir:value "active"];
  fhir:CodeSystem.experimental [ fhir:value "false"^^xsd:boolean];
  fhir:CodeSystem.date [ fhir:value "2019-01-29T00:00:00+00:00"^^xsd:dateTime];
  fhir:CodeSystem.publisher [ fhir:value "Systematic | Trifork"];
  fhir:CodeSystem.contact [
     fhir:index 0;
     fhir:ContactDetail.name [ fhir:value "Systematic | Trifork" ];
     fhir:ContactDetail.telecom [
       fhir:index 0;
       fhir:ContactPoint.system [ fhir:value "url" ];
       fhir:ContactPoint.value [ fhir:value "http://ehealth.sundhed.dk" ]     ]
  ];
  fhir:CodeSystem.description [ fhir:value "Quality codes for qualities with which a device can perform measuring"];
  fhir:CodeSystem.caseSensitive [ fhir:value "true"^^xsd:boolean];
  fhir:CodeSystem.content [ fhir:value "complete"];
  fhir:CodeSystem.concept [
     fhir:index 0;
     fhir:CodeSystem.concept.code [ fhir:value "none" ];
     fhir:CodeSystem.concept.display [ fhir:value "No quality needed" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Quality value where no derivation rule logic nor values are expected" ];
     fhir:CodeSystem.concept.designation [
       fhir:index 0;
       fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
       fhir:CodeSystem.concept.designation.value [ fhir:value "Ingen udstyrskvalitet krævet/ventet" ]     ];
     fhir:CodeSystem.concept.concept [
       fhir:index 0;
       fhir:CodeSystem.concept.code [ fhir:value "unknown" ];
       fhir:CodeSystem.concept.display [ fhir:value "Unknown quality" ];
       fhir:CodeSystem.concept.definition [ fhir:value "Unknown quality (Unlikely to be adequate if a quality value is expected)" ];
       fhir:CodeSystem.concept.designation [
         fhir:index 0;
         fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
         fhir:CodeSystem.concept.designation.value [ fhir:value "Ukendt udstyrskvalitet" ]       ];
       fhir:CodeSystem.concept.concept [
         fhir:index 0;
         fhir:CodeSystem.concept.code [ fhir:value "derivation-error" ];
         fhir:CodeSystem.concept.display [ fhir:value "Error in deriving or determining the quality" ];
         fhir:CodeSystem.concept.definition [ fhir:value "Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error" ];
         fhir:CodeSystem.concept.designation [
           fhir:index 0;
           fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
           fhir:CodeSystem.concept.designation.value [ fhir:value "Udstyrskvaliteten kunne ikke bestemmes grundet manglende input, utilgængelig logik, eller anden fejl." ]         ];
         fhir:CodeSystem.concept.concept [
           fhir:index 0;
           fhir:CodeSystem.concept.code [ fhir:value "normal" ];
           fhir:CodeSystem.concept.display [ fhir:value "Normal/neutral device measuring quality" ];
           fhir:CodeSystem.concept.definition [ fhir:value "Normal/neutral device measuring quality" ];
           fhir:CodeSystem.concept.designation [
             fhir:index 0;
             fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
             fhir:CodeSystem.concept.designation.value [ fhir:value "Normalt/neutralt udstyrskvalitetsniveau" ]           ];
           fhir:CodeSystem.concept.concept [
             fhir:index 0;
             fhir:CodeSystem.concept.code [ fhir:value "low-precision" ];
             fhir:CodeSystem.concept.display [ fhir:value "Low precision/credibility grade device quality" ];
             fhir:CodeSystem.concept.definition [ fhir:value "Low precision/credibility grade device quality. Typically such device is not clinical grade." ];
             fhir:CodeSystem.concept.designation [
               fhir:index 0;
               fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
               fhir:CodeSystem.concept.designation.value [ fhir:value "Lav præcision eller pålidelighed" ]             ];
             fhir:CodeSystem.concept.concept [
               fhir:index 0;
               fhir:CodeSystem.concept.code [ fhir:value "low-precision-degraded" ];
               fhir:CodeSystem.concept.display [ fhir:value "Degraded quality for low precision/credibility grade device" ];
               fhir:CodeSystem.concept.definition [ fhir:value "Degraded quality for low precision/credibility grade device. Typically such device is not clinical grade." ];
               fhir:CodeSystem.concept.designation [
                 fhir:index 0;
                 fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
                 fhir:CodeSystem.concept.designation.value [ fhir:value "Forringet kvalitet for udstyr med lav præcision eller pålidelighed" ]               ];
               fhir:CodeSystem.concept.concept [
                 fhir:index 0;
                 fhir:CodeSystem.concept.code [ fhir:value "low-precision-normal" ];
                 fhir:CodeSystem.concept.display [ fhir:value "Normal/neutral quality for low precision/credibility grade device" ];
                 fhir:CodeSystem.concept.definition [ fhir:value "Normal/neutral quality for low precision/credibility grade device. Typically such device is not clinical grade." ];
                 fhir:CodeSystem.concept.designation [
                   fhir:index 0;
                   fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
                   fhir:CodeSystem.concept.designation.value [ fhir:value "Normal kvalitet for udstyr med lav præcision eller pålidelighed" ]                 ];
                 fhir:CodeSystem.concept.concept [
                   fhir:index 0;
                   fhir:CodeSystem.concept.code [ fhir:value "low-precision-uncalibrated" ];
                   fhir:CodeSystem.concept.display [ fhir:value "Quality for uncalibrated low precision/credibility grade device" ];
                   fhir:CodeSystem.concept.definition [ fhir:value "Quality for uncalibrated low precision/credibility grade device. Typically such device is not clinical grade." ];
                   fhir:CodeSystem.concept.designation [
                     fhir:index 0;
                     fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
                     fhir:CodeSystem.concept.designation.value [ fhir:value "Kvalitet for ukalibreret udstyr med lav præcision eller pålidelighed" ]                   ];
                   fhir:CodeSystem.concept.concept [
                     fhir:index 0;
                     fhir:CodeSystem.concept.code [ fhir:value "low-precision-calibrated" ];
                     fhir:CodeSystem.concept.display [ fhir:value "Quality for calibrated low precision/credibility grade device" ];
                     fhir:CodeSystem.concept.definition [ fhir:value "Quality for calibrated low precision/credibility grade device. Typically such device is not clinical grade." ];
                     fhir:CodeSystem.concept.designation [
                       fhir:index 0;
                       fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
                       fhir:CodeSystem.concept.designation.value [ fhir:value "Kvalitet for kalibreret udstyr med lav præcision eller pålidelighed" ]                     ];
                     fhir:CodeSystem.concept.concept [
                       fhir:index 0;
                       fhir:CodeSystem.concept.code [ fhir:value "high-precision" ];
                       fhir:CodeSystem.concept.display [ fhir:value "High precision/credibility grade device quality" ];
                       fhir:CodeSystem.concept.definition [ fhir:value "High precision/credibility grade device quality. Typically such device is clinical grade." ];
                       fhir:CodeSystem.concept.designation [
                         fhir:index 0;
                         fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
                         fhir:CodeSystem.concept.designation.value [ fhir:value "Høj præcision eller pålidelighed" ]                       ];
                       fhir:CodeSystem.concept.concept [
                         fhir:index 0;
                         fhir:CodeSystem.concept.code [ fhir:value "high-precision-degraded" ];
                         fhir:CodeSystem.concept.display [ fhir:value "Degraded quality for high precision/credibility grade device" ];
                         fhir:CodeSystem.concept.definition [ fhir:value "Degraded quality for high precision/credibility grade device. Typically such device is clinical grade." ];
                         fhir:CodeSystem.concept.designation [
                           fhir:index 0;
                           fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
                           fhir:CodeSystem.concept.designation.value [ fhir:value "Forringet kvalitet for udstyr med høj præcision eller pålidelighed" ]                         ];
                         fhir:CodeSystem.concept.concept [
                           fhir:index 0;
                           fhir:CodeSystem.concept.code [ fhir:value "high-precision-normal" ];
                           fhir:CodeSystem.concept.display [ fhir:value "Normal/neutral quality for high precision/credibility grade device" ];
                           fhir:CodeSystem.concept.definition [ fhir:value "Normal/neutral quality for high precision/credibility grade device. Typically such device is clinical grade." ];
                           fhir:CodeSystem.concept.designation [
                             fhir:index 0;
                             fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
                             fhir:CodeSystem.concept.designation.value [ fhir:value "Normal kvalitet for udstyr med høj præcision eller pålidelighed" ]                           ];
                           fhir:CodeSystem.concept.concept [
                             fhir:index 0;
                             fhir:CodeSystem.concept.code [ fhir:value "high-precision-uncalibrated" ];
                             fhir:CodeSystem.concept.display [ fhir:value "Quality for uncalibrated high precision/credibility grade device" ];
                             fhir:CodeSystem.concept.definition [ fhir:value "Quality for uncalibrated high precision/credibility grade device. Typically such device is clinical grade." ];
                             fhir:CodeSystem.concept.designation [
                               fhir:index 0;
                               fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
                               fhir:CodeSystem.concept.designation.value [ fhir:value "Kvalitet for ukalibreret udstyr med høj præcision eller pålidelighed" ]                             ];
                             fhir:CodeSystem.concept.concept [
                               fhir:index 0;
                               fhir:CodeSystem.concept.code [ fhir:value "high-precision-calibrated" ];
                               fhir:CodeSystem.concept.display [ fhir:value "Quality for calibrated high precision/credibility grade device" ];
                               fhir:CodeSystem.concept.definition [ fhir:value "Quality for calibrated high precision/credibility grade device. Typically such device is clinical grade." ];
                               fhir:CodeSystem.concept.designation [
                                 fhir:index 0;
                                 fhir:CodeSystem.concept.designation.language [ fhir:value "da" ];
                                 fhir:CodeSystem.concept.designation.value [ fhir:value "Kvalitet for kalibreret udstyr med høj præcision eller pålidelighed" ]                               ]                             ]                           ]                         ]                       ]                     ]                   ]                 ]               ]             ]           ]         ]       ]     ]
  ], [
     fhir:index 1;
     fhir:CodeSystem.concept.code [ fhir:value "TBD" ];
     fhir:CodeSystem.concept.display [ fhir:value "Example value - Under construction" ];
     fhir:CodeSystem.concept.definition [ fhir:value "Example value - Under construction" ];
     fhir:CodeSystem.concept.property [
       fhir:index 0;
       fhir:CodeSystem.concept.property.code [ fhir:value "deprecated" ];
       fhir:CodeSystem.concept.property.valueDateTime [ fhir:value "2020-02-03"^^xsd:date ]     ]
  ].

# - ontology header ------------------------------------------------------------

 a owl:Ontology;
  owl:imports fhir:fhir.ttl.