@prefix fhir: . @prefix owl: . @prefix rdfs: . @prefix xsd: . # - resource ------------------------------------------------------------------- a fhir:CodeSystem ; fhir:nodeRole fhir:treeRoot ; fhir:id [ fhir:v "ehealth-usage-quality"] ; # fhir:text [ fhir:status [ fhir:v "generated" ] ; fhir:div "

This code system http://ehealth.sundhed.dk/cs/usage-quality defines the following codes:

LvlCodeDisplayDefinitionDansk (Danish, da)
1none No quality neededQuality value where no derivation rule logic nor values are expectedIngen betjeningskvalitet krævet/ventet
2  unknown Unknown qualityUnknown quality (Unlikely to be adequate if a quality value is expected)Ukendt betjeningskvalitet
3    derivation-error Error in deriving or determining the qualityQuality value could not be derived due to insufficient input, unknown/unavailable logic, or other errorBetjeningskvaliteten kunne ikke bestemmes grundet manglende input, utilgængelig logik, eller anden fejl.
4      normal Normal/neutral usage qualityNormal/neutral usage qualityNormal eller neutral betjeningskvalitet
5        instructions-followed Performed in accordance with instructionsPerformed in accordance with instructionsBrugsvejledning fulgt
5        instructions-not-followed Performed without following instructionsPerformed without following instructionsBrugsvejledning ej fulgt
5        entered-manually Manually entered measurementManually entered measurementManuelt indtastet måling
5        automatically-transferred Automatically transferred measurementAutomatically transferred measurementAutomatisk overført måling
1TBD Example value - Under constructionExample value - Under construction
1TBD2 Example value2 - Under constructionExample value2 - Under construction
" ] ; # fhir:url [ fhir:v "http://ehealth.sundhed.dk/cs/usage-quality"^^xsd:anyURI] ; # fhir:version [ fhir:v "2.8.0"] ; # fhir:name [ fhir:v "UsageQuality"] ; # fhir:title [ fhir:v "Usage Quality"] ; # fhir:status [ fhir:v "active"] ; # fhir:experimental [ fhir:v "false"^^xsd:boolean] ; # fhir:date [ fhir:v "2019-01-29T00:00:00+00:00"^^xsd:dateTime] ; # fhir:publisher [ fhir:v "Systematic | Trifork"] ; # fhir:contact ( [ fhir:name [ fhir:v "Systematic | Trifork" ] ; fhir:telecom ( [ fhir:system [ fhir:v "url" ] ; fhir:value [ fhir:v "http://ehealth.sundhed.dk" ] ] ) ] ) ; # fhir:description [ fhir:v "Quality codes for usage or operating of measuring device"] ; # fhir:caseSensitive [ fhir:v "true"^^xsd:boolean] ; # fhir:content [ fhir:v "complete"] ; # fhir:concept ( [ fhir:code [ fhir:v "none" ] ; fhir:display [ fhir:v "No quality needed" ] ; fhir:definition [ fhir:v "Quality value where no derivation rule logic nor values are expected" ] ; fhir:designation ( [ fhir:language [ fhir:v "da" ] ; fhir:value [ fhir:v "Ingen betjeningskvalitet krævet/ventet" ] ] ) ; fhir:concept ( [ fhir:code [ fhir:v "unknown" ] ; fhir:display [ fhir:v "Unknown quality" ] ; fhir:definition [ fhir:v "Unknown quality (Unlikely to be adequate if a quality value is expected)" ] ; fhir:designation ( [ fhir:language [ fhir:v "da" ] ; fhir:value [ fhir:v "Ukendt betjeningskvalitet" ] ] ) ; fhir:concept ( [ fhir:code [ fhir:v "derivation-error" ] ; fhir:display [ fhir:v "Error in deriving or determining the quality" ] ; fhir:definition [ fhir:v "Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error" ] ; fhir:designation ( [ fhir:language [ fhir:v "da" ] ; fhir:value [ fhir:v "Betjeningskvaliteten kunne ikke bestemmes grundet manglende input, utilgængelig logik, eller anden fejl." ] ] ) ; fhir:concept ( [ fhir:code [ fhir:v "normal" ] ; fhir:display [ fhir:v "Normal/neutral usage quality" ] ; fhir:definition [ fhir:v "Normal/neutral usage quality" ] ; fhir:designation ( [ fhir:language [ fhir:v "da" ] ; fhir:value [ fhir:v "Normal eller neutral betjeningskvalitet" ] ] ) ; fhir:concept ( [ fhir:code [ fhir:v "instructions-followed" ] ; fhir:display [ fhir:v "Performed in accordance with instructions" ] ; fhir:definition [ fhir:v "Performed in accordance with instructions" ] ; fhir:designation ( [ fhir:language [ fhir:v "da" ] ; fhir:value [ fhir:v "Brugsvejledning fulgt" ] ] ) ] [ fhir:code [ fhir:v "instructions-not-followed" ] ; fhir:display [ fhir:v "Performed without following instructions" ] ; fhir:definition [ fhir:v "Performed without following instructions" ] ; fhir:designation ( [ fhir:language [ fhir:v "da" ] ; fhir:value [ fhir:v "Brugsvejledning ej fulgt" ] ] ) ] [ fhir:code [ fhir:v "entered-manually" ] ; fhir:display [ fhir:v "Manually entered measurement" ] ; fhir:definition [ fhir:v "Manually entered measurement" ] ; fhir:designation ( [ fhir:language [ fhir:v "da" ] ; fhir:value [ fhir:v "Manuelt indtastet måling" ] ] ) ] [ fhir:code [ fhir:v "automatically-transferred" ] ; fhir:display [ fhir:v "Automatically transferred measurement" ] ; fhir:definition [ fhir:v "Automatically transferred measurement" ] ; fhir:designation ( [ fhir:language [ fhir:v "da" ] ; fhir:value [ fhir:v "Automatisk overført måling" ] ] ) ] ) ] ) ] ) ] ) ] [ fhir:code [ fhir:v "TBD" ] ; fhir:display [ fhir:v "Example value - Under construction" ] ; fhir:definition [ fhir:v "Example value - Under construction" ] ; fhir:property ( [ fhir:code [ fhir:v "deprecated" ] ; fhir:value [ fhir:v "2020-02-03"^^xsd:date ] ] ) ] [ fhir:code [ fhir:v "TBD2" ] ; fhir:display [ fhir:v "Example value2 - Under construction" ] ; fhir:definition [ fhir:v "Example value2 - Under construction" ] ; fhir:property ( [ fhir:code [ fhir:v "deprecated" ] ; fhir:value [ fhir:v "2020-02-03"^^xsd:date ] ] ) ] ) . # # -------------------------------------------------------------------------------------