eHealth Infrastructure
latest - ci-build

eHealth Infrastructure - Local Development build (vlatest) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: Task Category - TTL Representation

Active as of 2019-01-29

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CodeSystem ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "ehealth-task-category"] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>This case-sensitive code system <code>http://ehealth.sundhed.dk/cs/task-category</code> defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>Dansk (Danish, da)</b></td></tr><tr><td style=\"white-space:nowrap\">TBD<a name=\"ehealth-task-category-TBD\"> </a></td><td>Example value - Under construction</td><td>Example value - Under construction</td><td/></tr><tr><td style=\"white-space:nowrap\">MissingMeasurementResolving<a name=\"ehealth-task-category-MissingMeasurementResolving\"> </a></td><td>Need resolving of why scheduled measurement has not been submitted</td><td>Need resolving of why scheduled measurement has not been submitted</td><td>Undersøg hvorfor der ikke er indsendt Måledata (måling og/eller spørgeskemabesvarelse).</td></tr><tr><td style=\"white-space:nowrap\">UnexpectedMeasurementResolving<a name=\"ehealth-task-category-UnexpectedMeasurementResolving\"> </a></td><td>Need resolving of why unexpected measurement was submitted</td><td>Need resolving of why unexpected measurement was submitted</td><td>Undersøg hvorfor der uventet er indsendt Måledata (måling og/eller spørgeskemabesvarelse).</td></tr><tr><td style=\"white-space:nowrap\">MeasurementForAssessment<a name=\"ehealth-task-category-MeasurementForAssessment\"> </a></td><td>Need assessment of measurement</td><td>Need assessment of measurement</td><td>Måledata (måling og/eller spørgeskemabesvarelse) er modtaget og klar til vurdering</td></tr><tr><td style=\"white-space:nowrap\">OpenSSLOrder<a name=\"ehealth-task-category-OpenSSLOrder\"> </a></td><td>Need processing of open SSL order</td><td>Need processing of open SSL order</td><td>Behandling af åben SSL bestilling</td></tr><tr><td style=\"white-space:nowrap\">CalibrationNeeded<a name=\"ehealth-task-category-CalibrationNeeded\"> </a></td><td>Device in need of calibration</td><td>Device in need of calibration</td><td>Måleudstyr har behov for kalibrering</td></tr><tr><td style=\"white-space:nowrap\">MeasurementForAssessmentFailureInAutoProcessing<a name=\"ehealth-task-category-MeasurementForAssessmentFailureInAutoProcessing\"> </a></td><td>Measurement Assessment failure during automated processing</td><td>Measurement Assessment failure during automated processing</td><td>Indsendte måledata (måling og/eller spørgeskemabesvarelse) kunne ikke vurderes af systemet. Du skal selv vurdere måledata.</td></tr><tr><td style=\"white-space:nowrap\">LibraryUseMismatchFixingNeeded<a name=\"ehealth-task-category-LibraryUseMismatchFixingNeeded\"> </a></td><td>Input and rule did not match</td><td>Input and rule did not match</td><td>Input og regel passer ikke sammen</td></tr><tr><td style=\"white-space:nowrap\">RefRangeNeeded<a name=\"ehealth-task-category-RefRangeNeeded\"> </a></td><td>Missing reference range required for automated processing</td><td>Missing reference range required for automated processing</td><td>Opsætning af grænseværdi mangler, hvilket er nødvendig for at systemet kan foretage vurdering</td></tr><tr><td style=\"white-space:nowrap\">RefRangeFixingNeeded<a name=\"ehealth-task-category-RefRangeFixingNeeded\"> </a></td><td>Reference range required for automated processing needs fixing</td><td>Reference range required for automated processing needs fixing</td><td>Grænseværdiopsætning er forkert og justering er nødvendig for at systemet kan foretage vurdering</td></tr><tr><td style=\"white-space:nowrap\">RefBaseNeeded<a name=\"ehealth-task-category-RefBaseNeeded\"> </a></td><td>Missing in force reference base required for automatic processing</td><td>Missing in force reference base required for automatic processing</td><td>Der mangler en referenceværdi for at måledata (måling eller spørgeskemabesvarelse) kan vurderes af systemet</td></tr><tr><td style=\"white-space:nowrap\">RefBaseFixingNeeded<a name=\"ehealth-task-category-RefBaseFixingNeeded\"> </a></td><td>In force reference base required for automatic processing needs fixing</td><td>In force reference base required for automatic processing needs fixing</td><td>Referenceværdi er forkert og justering er nødvendig for at systemet kan foretage vurdering</td></tr><tr><td style=\"white-space:nowrap\">RequiredQuestionAnswerMissing<a name=\"ehealth-task-category-RequiredQuestionAnswerMissing\"> </a></td><td>Missing question answers required for automated processing</td><td>Missing question answers required for automated processing</td><td>Spørgsmål mangler besvarelse i spørgeskemabesvarelse for at vurdering af spørgeskemabesvarelse kan foretages af systemet</td></tr><tr><td style=\"white-space:nowrap\">ExpectedDelivery<a name=\"ehealth-task-category-ExpectedDelivery\"> </a></td><td>Delivery expected</td><td>Delivery expected</td><td>Forventet levering</td></tr><tr><td style=\"white-space:nowrap\">MeasurementForAssessmentNotTriaged<a name=\"ehealth-task-category-MeasurementForAssessmentNotTriaged\"> </a></td><td>Need assessment of measurement where triage was not performed during automated processing</td><td>Need assessment of measurement where triage was not performed during automated processing</td><td>Indsendte måledata (måling og/eller spørgeskemabesvarelse) er ikke vurderet af systemet. Du skal selv vurdere måledata.</td></tr><tr><td style=\"white-space:nowrap\">MeasurementForAssessmentAbsentValue<a name=\"ehealth-task-category-MeasurementForAssessmentAbsentValue\"> </a></td><td>Need assessment of measurement with absent value</td><td>Need assessment of measurement with absent value</td><td>Indsendte måledata (måling) har fravær af målt værdi.</td></tr></table></div>"
  ] ; # 
  fhir:url [ fhir:v "http://ehealth.sundhed.dk/cs/task-category"^^xsd:anyURI] ; # 
  fhir:version [ fhir:v "latest"] ; # 
  fhir:name [ fhir:v "TaskCategory"] ; # 
  fhir:title [ fhir:v "Task Category"] ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:experimental [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:date [ fhir:v "2019-01-29T00:00:00+00:00"^^xsd:dateTime] ; # 
  fhir:publisher [ fhir:v "Den telemedicinske infrastruktur (eHealth Infrastructure)"] ; # 
  fhir:contact ( [
fhir:name [ fhir:v "Den telemedicinske infrastruktur (eHealth Infrastructure)" ] ;
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "http://ehealth.sundhed.dk" ]     ] )
  ] ) ; # 
  fhir:description [ fhir:v "Task Category"] ; # 
  fhir:caseSensitive [ fhir:v "true"^^xsd:boolean] ; # 
  fhir:content [ fhir:v "complete"] ; # 
  fhir:concept ( [
fhir:code [ fhir:v "TBD" ] ;
fhir:display [ fhir:v "Example value - Under construction" ] ;
fhir:definition [ fhir:v "Example value - Under construction" ] ;
    ( fhir:property [
fhir:code [ fhir:v "deprecated" ] ;
fhir:value [ fhir:v "2020-02-27"^^xsd:date ]     ] )
  ] [
fhir:code [ fhir:v "MissingMeasurementResolving" ] ;
fhir:display [ fhir:v "Need resolving of why scheduled measurement has not been submitted" ] ;
fhir:definition [ fhir:v "Need resolving of why scheduled measurement has not been submitted" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Undersøg hvorfor der ikke er indsendt Måledata (måling og/eller spørgeskemabesvarelse)." ]     ] )
  ] [
fhir:code [ fhir:v "UnexpectedMeasurementResolving" ] ;
fhir:display [ fhir:v "Need resolving of why unexpected measurement was submitted" ] ;
fhir:definition [ fhir:v "Need resolving of why unexpected measurement was submitted" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Undersøg hvorfor der uventet er indsendt Måledata (måling og/eller spørgeskemabesvarelse)." ]     ] )
  ] [
fhir:code [ fhir:v "MeasurementForAssessment" ] ;
fhir:display [ fhir:v "Need assessment of measurement" ] ;
fhir:definition [ fhir:v "Need assessment of measurement" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Måledata (måling og/eller spørgeskemabesvarelse) er modtaget og klar til vurdering" ]     ] )
  ] [
fhir:code [ fhir:v "OpenSSLOrder" ] ;
fhir:display [ fhir:v "Need processing of open SSL order" ] ;
fhir:definition [ fhir:v "Need processing of open SSL order" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Behandling af åben SSL bestilling" ]     ] )
  ] [
fhir:code [ fhir:v "CalibrationNeeded" ] ;
fhir:display [ fhir:v "Device in need of calibration" ] ;
fhir:definition [ fhir:v "Device in need of calibration" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Måleudstyr har behov for kalibrering" ]     ] )
  ] [
fhir:code [ fhir:v "MeasurementForAssessmentFailureInAutoProcessing" ] ;
fhir:display [ fhir:v "Measurement Assessment failure during automated processing" ] ;
fhir:definition [ fhir:v "Measurement Assessment failure during automated processing" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Indsendte måledata (måling og/eller spørgeskemabesvarelse) kunne ikke vurderes af systemet. Du skal selv vurdere måledata." ]     ] )
  ] [
fhir:code [ fhir:v "LibraryUseMismatchFixingNeeded" ] ;
fhir:display [ fhir:v "Input and rule did not match" ] ;
fhir:definition [ fhir:v "Input and rule did not match" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Input og regel passer ikke sammen" ]     ] )
  ] [
fhir:code [ fhir:v "RefRangeNeeded" ] ;
fhir:display [ fhir:v "Missing reference range required for automated processing" ] ;
fhir:definition [ fhir:v "Missing reference range required for automated processing" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Opsætning af grænseværdi mangler, hvilket er nødvendig for at systemet kan foretage vurdering" ]     ] )
  ] [
fhir:code [ fhir:v "RefRangeFixingNeeded" ] ;
fhir:display [ fhir:v "Reference range required for automated processing needs fixing" ] ;
fhir:definition [ fhir:v "Reference range required for automated processing needs fixing" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Grænseværdiopsætning er forkert og justering er nødvendig for at systemet kan foretage vurdering" ]     ] )
  ] [
fhir:code [ fhir:v "RefBaseNeeded" ] ;
fhir:display [ fhir:v "Missing in force reference base required for automatic processing" ] ;
fhir:definition [ fhir:v "Missing in force reference base required for automatic processing" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Der mangler en referenceværdi for at måledata (måling eller spørgeskemabesvarelse) kan vurderes af systemet" ]     ] )
  ] [
fhir:code [ fhir:v "RefBaseFixingNeeded" ] ;
fhir:display [ fhir:v "In force reference base required for automatic processing needs fixing" ] ;
fhir:definition [ fhir:v "In force reference base required for automatic processing needs fixing" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Referenceværdi er forkert og justering er nødvendig for at systemet kan foretage vurdering" ]     ] )
  ] [
fhir:code [ fhir:v "RequiredQuestionAnswerMissing" ] ;
fhir:display [ fhir:v "Missing question answers required for automated processing" ] ;
fhir:definition [ fhir:v "Missing question answers required for automated processing" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Spørgsmål mangler besvarelse i spørgeskemabesvarelse for at vurdering af spørgeskemabesvarelse kan foretages af systemet" ]     ] )
  ] [
fhir:code [ fhir:v "ExpectedDelivery" ] ;
fhir:display [ fhir:v "Delivery expected" ] ;
fhir:definition [ fhir:v "Delivery expected" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Forventet levering" ]     ] )
  ] [
fhir:code [ fhir:v "MeasurementForAssessmentNotTriaged" ] ;
fhir:display [ fhir:v "Need assessment of measurement where triage was not performed during automated processing" ] ;
fhir:definition [ fhir:v "Need assessment of measurement where triage was not performed during automated processing" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Indsendte måledata (måling og/eller spørgeskemabesvarelse) er ikke vurderet af systemet. Du skal selv vurdere måledata." ]     ] )
  ] [
fhir:code [ fhir:v "MeasurementForAssessmentAbsentValue" ] ;
fhir:display [ fhir:v "Need assessment of measurement with absent value" ] ;
fhir:definition [ fhir:v "Need assessment of measurement with absent value" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Indsendte måledata (måling) har fravær af målt værdi." ]     ] )
  ] ) . #