eHealth Infrastructure
latest - ci-build

eHealth Infrastructure - Local Development build (vlatest) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

OperationDefinition: Execute patient devices

Official URL: https://reporting.devtest.systematic-ehealth.com/fhir/OperationDefinition/-s-execute-patient-devices Version: latest
Active as of 2024-06-07 Computable Name: execute-patient-devices

Report Contents

This report contains Device information for each EpisodeOfCare:

  • Device
  • DeviceUseStatement
  • DeviceMetrics

    Grouping

    This report is grouped by EpsiodeOfCare. Each group is returned in a separate JSon file.

    Parameters

  • organization: Filter on EpisodeOfCare.managingOrganization match
  • period: Filter on DeviceUseStatement.whenUsed overlap

    Output

    Output can be found in Binary.content. This is a Base64 encoded .zip file containing JSon files corresponding to the report groups.

    Example output

    All returned objects are Fhir resources. See the implementation guide for details

    { ‘EHealthEpisodeOfCare’: { ‘resourceType’: ‘EpisodeOfCare’, ‘id’: ‘F417C17F9FDE24C9090BD629C8EE1697’, ‘meta’: { ‘versionId’: ‘1’, ‘profile’: [‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-episodeofcare’] }, ‘extension’: [{ ‘url’: ‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-episodeofcare-caremanagerOrganization’, ‘valueReference’: { ‘reference’: ‘https://organization.local.ehealth.sundhed.dk/fhir/Organization/313D8B0E0AC8EA8169D1DA45ECEEACB9’ } } ], ‘status’: ‘active’, ‘diagnosis’: [{ ‘condition’: { ‘reference’: ‘https://careplan.local.ehealth.sundhed.dk/fhir/Condition/9A7FCD55CA3031585A8F1690DB1D8034’ }, ‘rank’: 1 } ], ‘patient’: { ‘reference’: ‘https://patient.local.ehealth.sundhed.dk/fhir/Patient/A1D94F323D8EF09E5D913D9522FD83C4’ }, ‘managingOrganization’: { ‘reference’: ‘https://organization.local.ehealth.sundhed.dk/fhir/Organization/8DC75F2B12BCC832F92CC065C3D0B451’ }, ‘period’: { ‘start’: ‘1970-01-01T01:00:01+01:00’, ‘end’: ‘1970-01-01T01:01:40+01:00’ } }, ‘EHealthDeviceUseStatement’: [{ ‘resourceType’: ‘DeviceUseStatement’, ‘id’: ‘9541E8EAEAD24376F208D5CD8A4D25F5’, ‘meta’: { ‘versionId’: ‘1’, ‘profile’: [‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement’] }, ‘extension’: [{ ‘url’: ‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context’, ‘valueReference’: { ‘reference’: ‘https://careplan.local.ehealth.sundhed.dk/fhir/CarePlan/23D34B29DD02EB232B6575537FE8ADC5’ } } ], ‘status’: ‘active’, ‘subject’: { ‘reference’: ‘https://patient.local.ehealth.sundhed.dk/fhir/Patient/AC38B1F6391F256002E5A7BE69CB2586’ }, ‘device’: { ‘reference’: ‘https://device.local.ehealth.sundhed.dk/fhir/Device/08D51B81A7FE5B480278150A94D4048A’ } } ], ‘EHealthDevice’: [{ ‘resourceType’: ‘Device’, ‘id’: ‘08D51B81A7FE5B480278150A94D4048A’, ‘meta’: { ‘versionId’: ‘1’, ‘profile’: [‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device’] }, ‘extension’: [{ ‘url’: ‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-privatelyOwned’, ‘valueBoolean’: true } ], ‘status’: ‘active’ } ], ‘EHealthDeviceMetric’: [{ ‘resourceType’: ‘DeviceMetric’, ‘id’: ‘7EA21ACD27EE012439F1440574A6BB21’, ‘meta’: { ‘versionId’: ‘1’, ‘profile’: [‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric’] }, ‘extension’: [{ ‘url’: ‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-qualities’, ‘extension’: [{ ‘url’: ‘category’, ‘valueCodeableConcept’: { ‘coding’: [{ ‘system’: ‘http://ehealth.sundhed.dk/cs/devicemetric-quality-types’, ‘code’: ‘initial’ } ] } }, { ‘url’: ‘value’, ‘valueInteger’: 5 } ] }, { ‘url’: ‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities’, ‘extension’: [{ ‘url’: ‘category’, ‘valueCodeableConcept’: { ‘coding’: [{ ‘system’: ‘http://ehealth.sundhed.dk/cs/devicemetric-quality-types’, ‘code’: ‘initial’ } ] } }, { ‘url’: ‘value’, ‘valueInteger’: 10 } ] }, { ‘url’: ‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities’, ‘extension’: [{ ‘url’: ‘category’, ‘valueCodeableConcept’: { ‘coding’: [{ ‘system’: ‘http://ehealth.sundhed.dk/cs/devicemetric-quality-types’, ‘code’: ‘initial’ } ] } }, { ‘url’: ‘value’, ‘valueInteger’: 12 } ] }, { ‘url’: ‘http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities’, ‘extension’: [{ ‘url’: ‘category’, ‘valueCodeableConcept’: { ‘coding’: [{ ‘system’: ‘http://ehealth.sundhed.dk/cs/devicemetric-quality-types’, ‘code’: ‘initial’ } ] } }, { ‘url’: ‘value’, ‘valueInteger’: 14 } ] } ], ‘identifier’: { ‘value’: ‘Foo’ }, ‘type’: { ‘text’: ‘code’ }, ‘source’: { ‘reference’: ‘https://device.local.ehealth.sundhed.dk/fhir/Device/08D51B81A7FE5B480278150A94D4048A’ }, ‘category’: ‘calculation’ } ] }

URL: [base]/$execute-patient-devices

Parameters

UseNameScopeCardinalityTypeBindingDocumentation
INanonymization1..1string
INorganization0..1Reference
INperiod0..1Period
INdevicetype0..1Coding
OUTreturn0..1Binary