eHealth Infrastructure
latest - ci-build

eHealth Infrastructure - Local Development build (vlatest) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

ValueSet: ClinicalImpression Finding Codes (Experimental)

Official URL: http://ehealth.sundhed.dk/vs/clinicalimpression-finding-codes Version: latest
Active as of 2019-02-08 Computable Name: ClinicalImpressionFindingCodes

Value set of clinical impression finding codes.

References

Logical Definition (CLD)

This value set includes codes based on the following rules:

  • Include all codes defined in http://ehealth.sundhed.dk/cs/clinicalimpression-finding-codes
  • Import all the codes that are contained in Observation Codes
  • Include these codes as defined in http://snomed.info/sct
    CodeDisplayEnglish (United States) (English (United States), en)Dansk (Danish, da)
    281300000Below reference rangeBelow reference range
    281302008Above reference rangeAbove reference range
    281301001Within reference rangeWithin reference range
    394844007Outside reference rangeOutside reference range
    442686002Measurement finding below reference rangeMeasurement finding below reference range
    442756004Measurement finding above reference rangeMeasurement finding above reference range
    442082004Measurement finding within reference rangeMeasurement finding within reference range
    442096005Measurement finding outside reference rangeMeasurement finding outside reference range
    449171008Oxygen saturation below reference rangeOxygen saturation below reference range
    448225001Oxygen saturation within reference rangeOxygen saturation within reference range
  • Include these codes as defined in urn:oid:1.2.208.184.100.1
    CodeDisplayDefinitionEnglish (United States) (English (United States), en)Dansk (Danish, da)
    RALTerapeutiske grænseværdier for RØD alarmTerapeutiske grænseværdier for RØD alarmTerapeutiske grænseværdier for RØD alarm
    GALTerapeutiske grænseværdier for GUL alarmTerapeutiske grænseværdier for GUL alarmTerapeutiske grænseværdier for GUL alarm
  • Include these codes as defined in http://ehealth.sundhed.dk/cs/reference-range-type
    CodeDisplayDefinitionEnglish (United States) (English (United States), en)Dansk (Danish, da)
    RELRALTerapeutic relative reference range for RED alarmTerapeutic relative reference range for RED alarmTerapeutiske relative grænseværdier for RØD alarm
    RELGALTerapeutic relative reference range for YELLOW alarmTerapeutic relative reference range for YELLOW alarmTerapeutiske relative grænseværdier for GUL alarm

 

Expansion

This value set contains 39 concepts.

CodeSystemDisplayDefinition
  red-question-answerhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesred question and answer combination

Applied to a single question and answer pair, this indicates a red combination. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates at least one red combination found.

  yellow-question-answerhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesyellow question and answer combination

Applied to a single question and answer pair, this indicates a yellow combination. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates at least one yellow combination found and no red combinations found.

  green-question-answerhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesgreen question and answer combination

Applied to a single question and answer pair, this indicates a green combination. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates at least one green combination found and no red or yellow combinations found.

  no-effective-answer-significancehttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesno effective answer significance for answer and question combination

Applied to a single question and answer pair, this indicates that answer did not meet any answer significance conditions. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates that no answer met the conditions of any answer significance(s) in the related question.

  no-answer-significance-definedhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesno answer significance defined for question(s)

Applied to a single question and answer pair, this indicates that the question did not have any answer significance. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates that no question had any associated answer significance(s).

  redhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesRed overall assessment

Overall assessment is red

  yellowhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesYellow overall assessment

Overall assessment is yellow

  greenhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesGreen overall assessment

Overall assessment is green

  data-absenthttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesmeasurement data is absent

measurement data is absent

  TBDhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesExample value - Under construction

Example value - Under construction

  NPU03011urn:oid:1.2.208.176.2.1O2 sat.;Hb(aB)

Hb(Fe; O2-bind.; aB)—Oxygen(O2); mætn. = ?

  NPU21692urn:oid:1.2.208.176.2.1Puls;Hjerte

Hjerte—Systole; frekv. = ? × 1/min

  NPU03804urn:oid:1.2.208.176.2.1Legeme vægt; Pt

Pt—Legeme; masse = ? kg

  NPU27281urn:oid:1.2.208.176.2.1Pt—Legeme; massekoefficient(masse/kvadreret højde) = ? kg/m²

Pt—Legeme; massekoefficient(masse/kvadreret højde) = ? kg/m²

  NPU03794urn:oid:1.2.208.176.2.1Pt—Legeme; højde = ? m

Pt—Legeme; højde = ? m

  MCS88015urn:oid:1.2.208.184.100.8FEV1;Lunge

Lunge—Lungefunktionsundersøgelse FEV1; vol. = ? L

  MCS88016urn:oid:1.2.208.184.100.8FVC;Lunge

Lunge—Lungefunktionsundersøgelse vitalkapasitet FVC; vol. = ? L

  MCS88017urn:oid:1.2.208.184.100.8FEV1/FVC;Lunge

Lunge—FEV1/FVC; ratio = ?

  MCS88019urn:oid:1.2.208.184.100.8Blodtryk hjemme systolisk;Arm

Arm—Blodtryk(systolisk) hjemme; tryk = ? mmHg

  MCS88020urn:oid:1.2.208.184.100.8Blodtryk hjemme diastolisk;Arm

Arm—Blodtryk(diastolisk) hjemme; tryk = ? mmHg

  MCS88021urn:oid:1.2.208.184.100.8MRC skala;Pt(KOL)

Pt(KOL) —MRC skala; arb.antal(værdi 1-5) = ?

  MCS88023urn:oid:1.2.208.184.100.8FEV1 af forventet værdi;Pt(KOL)

Pt(KOL) - FEV1 i % af den forventede værdi (efter højde,alder og køn); ratio = ?

  MCS88050urn:oid:1.2.208.184.100.8Rejse sætte sig testen;Pt

Pt—Rejse sætte sig testen; antal (værdi 0-50) = × 1/ 30 sek

  MCS88137urn:oid:1.2.208.184.100.8CAT score;Pt

Pt—CORD Assessment Test (CAT) score; antal(værdi 0-40) = ?

  ZZ3170urn:oid:1.2.208.176.2.4Hjemmeblodtryksmåling udført af patienten
  281300000http://snomed.info/sctBelow reference range
  281302008http://snomed.info/sctAbove reference range
  281301001http://snomed.info/sctWithin reference range
  394844007http://snomed.info/sctOutside reference range (qualifier value)
  442686002http://snomed.info/sctMeasurement finding below reference range (finding)
  442756004http://snomed.info/sctMeasurement finding above reference range
  442082004http://snomed.info/sctMeasurement finding within reference range
  442096005http://snomed.info/sctMeasurement finding outside reference range
  449171008http://snomed.info/sctOxygen saturation below reference range (finding)
  448225001http://snomed.info/sctOxygen saturation within reference range (finding)
  RALurn:oid:1.2.208.184.100.1Terapeutiske grænseværdier for RØD alarm

Terapeutiske grænseværdier for RØD alarm

  GALurn:oid:1.2.208.184.100.1Terapeutiske grænseværdier for GUL alarm

Terapeutiske grænseværdier for GUL alarm

  RELRALhttp://ehealth.sundhed.dk/cs/reference-range-typeTerapeutic relative reference range for RED alarm

Terapeutic relative reference range for RED alarm

  RELGALhttp://ehealth.sundhed.dk/cs/reference-range-typeTerapeutic relative reference range for YELLOW alarm

Terapeutic relative reference range for YELLOW alarm


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code