eHealth Infrastructure
latest - ci-build

eHealth Infrastructure - Local Development build (vlatest) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

ValueSet: Reference Range Type (Experimental)

Official URL: http://ehealth.sundhed.dk/vs/reference-range-type Version: latest
Active as of 2019-02-08 Computable Name: ReferenceRangeType

Reference Range type value set.

References

Logical Definition (CLD)

This value set includes codes based on the following rules:

 

Expansion

This value set contains 34 concepts.

CodeSystemDisplayDefinition
  typehttp://terminology.hl7.org/CodeSystem/referencerange-meaningType

General types of reference range.

  normalhttp://terminology.hl7.org/CodeSystem/referencerange-meaningNormal Range

Values expected for a normal member of the relevant control population being measured. Typically each results producer such as a laboratory has specific normal ranges and they are usually defined as within two standard deviations from the mean and account for 95.45% of this population.

  recommendedhttp://terminology.hl7.org/CodeSystem/referencerange-meaningRecommended Range

The range that is recommended by a relevant professional body.

  treatmenthttp://terminology.hl7.org/CodeSystem/referencerange-meaningTreatment Range

The range at which treatment would/should be considered.

  therapeutichttp://terminology.hl7.org/CodeSystem/referencerange-meaningTherapeutic Desired Level

The optimal range for best therapeutic outcomes.

  prehttp://terminology.hl7.org/CodeSystem/referencerange-meaningPre Therapeutic Desired Level

The optimal range for best therapeutic outcomes for a specimen taken immediately before administration.

  posthttp://terminology.hl7.org/CodeSystem/referencerange-meaningPost Therapeutic Desired Level

The optimal range for best therapeutic outcomes for a specimen taken immediately after administration.

  endocrinehttp://terminology.hl7.org/CodeSystem/referencerange-meaningEndocrine

Endocrine related states that change the expected value.

  pre-pubertyhttp://terminology.hl7.org/CodeSystem/referencerange-meaningPre-Puberty

An expected range in an individual prior to puberty.

  follicularhttp://terminology.hl7.org/CodeSystem/referencerange-meaningFollicular Stage

An expected range in an individual during the follicular stage of the cycle.

  midcyclehttp://terminology.hl7.org/CodeSystem/referencerange-meaningMidCycle

An expected range in an individual during the midcycle stage of the cycle.

  lutealhttp://terminology.hl7.org/CodeSystem/referencerange-meaningLuteal

An expected range in an individual during the luteal stage of the cycle.

  postmenopausalhttp://terminology.hl7.org/CodeSystem/referencerange-meaningPost-Menopause

An expected range in an individual post-menopause.

  NPU03011urn:oid:1.2.208.176.2.1O2 sat.;Hb(aB)

Hb(Fe; O2-bind.; aB)—Oxygen(O2); mætn. = ?

  NPU21692urn:oid:1.2.208.176.2.1Puls;Hjerte

Hjerte—Systole; frekv. = ? × 1/min

  NPU03804urn:oid:1.2.208.176.2.1Legeme vægt; Pt

Pt—Legeme; masse = ? kg

  NPU27281urn:oid:1.2.208.176.2.1Pt—Legeme; massekoefficient(masse/kvadreret højde) = ? kg/m²

Pt—Legeme; massekoefficient(masse/kvadreret højde) = ? kg/m²

  NPU03794urn:oid:1.2.208.176.2.1Pt—Legeme; højde = ? m

Pt—Legeme; højde = ? m

  MCS88015urn:oid:1.2.208.184.100.8FEV1;Lunge

Lunge—Lungefunktionsundersøgelse FEV1; vol. = ? L

  MCS88016urn:oid:1.2.208.184.100.8FVC;Lunge

Lunge—Lungefunktionsundersøgelse vitalkapasitet FVC; vol. = ? L

  MCS88017urn:oid:1.2.208.184.100.8FEV1/FVC;Lunge

Lunge—FEV1/FVC; ratio = ?

  MCS88019urn:oid:1.2.208.184.100.8Blodtryk hjemme systolisk;Arm

Arm—Blodtryk(systolisk) hjemme; tryk = ? mmHg

  MCS88020urn:oid:1.2.208.184.100.8Blodtryk hjemme diastolisk;Arm

Arm—Blodtryk(diastolisk) hjemme; tryk = ? mmHg

  MCS88021urn:oid:1.2.208.184.100.8MRC skala;Pt(KOL)

Pt(KOL) —MRC skala; arb.antal(værdi 1-5) = ?

  MCS88023urn:oid:1.2.208.184.100.8FEV1 af forventet værdi;Pt(KOL)

Pt(KOL) - FEV1 i % af den forventede værdi (efter højde,alder og køn); ratio = ?

  MCS88050urn:oid:1.2.208.184.100.8Rejse sætte sig testen;Pt

Pt—Rejse sætte sig testen; antal (værdi 0-50) = × 1/ 30 sek

  MCS88137urn:oid:1.2.208.184.100.8CAT score;Pt

Pt—CORD Assessment Test (CAT) score; antal(værdi 0-40) = ?

  ZZ3170urn:oid:1.2.208.176.2.4Hjemmeblodtryksmåling udført af patienten
  RALurn:oid:1.2.208.184.100.1Terapeutiske grænseværdier for RØD alarm

Terapeutiske grænseværdier for RØD alarm

  GALurn:oid:1.2.208.184.100.1Terapeutiske grænseværdier for GUL alarm

Terapeutiske grænseværdier for GUL alarm

  TBDhttp://ehealth.sundhed.dk/cs/reference-range-typeExample value - Under construction

Example value - Under construction

  TBD2http://ehealth.sundhed.dk/cs/reference-range-typeExample value2 - Under construction

Example value2 - Under construction

  RELRALhttp://ehealth.sundhed.dk/cs/reference-range-typeTerapeutic relative reference range for RED alarm

Terapeutic relative reference range for RED alarm

  RELGALhttp://ehealth.sundhed.dk/cs/reference-range-typeTerapeutic relative reference range for YELLOW alarm

Terapeutic relative reference range for YELLOW alarm


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code