The DeviceUseStatement resource represents a record of a device being used by a patient in the context of a careplan over a certain period of time.
This resource records the use of a healthcare-related device by a patient in the context of a careplan. The resource can be used to note the use of a clinical device such as a spyrometer, blood pressure monitor, and other devices required to fulfil the careplan.
If the same device is used simultaneously for the fulfilment of more than one careplan for the same patient, then more than one active DeviceUseStatement will exist.
A DeviceUseStatement is considered active only when its status field is Active
. For logging purposes the whenUsed
element is updated to reflect the period in which the DeviceUseStatement is active; but this element alone does not indicate whether the the DeviceUseStatement is Active
or not. A DeviceUseStatement which is Active
will have a whenUsed.end
which is null
.
DeviceUseStatements which have been in status Active
cannot be deleted.
DeviceUseStatements resources are created and updated automatically based on actions and information provided in the Service, Support & Logistics (SSL) domain of the eHealth Infrastructure. The use of DeviceUseStatements therefore concerns reading and searching only.
The life cycle of DeviceUseStatement resources is normally managed by the SSL subsystem, when an SSL supplier or a practitioner signals that a device has been delivered to a patient. At this time the Device Service is searched for an existing instance of this Device resource and a DeviceUseStatement referencing this Device is created.
When the SSL subsystem is signaled that a Device is no longer being used, it will update the corresponding DeviceUseStatement automatically.
It is possible for a Practitioner (as opposed to the SSL subsystem) to also create and maintain DeviceUseStatements; and also to override what was set by the SSL subsystem.
It can be relevant for a Practitioner to create a DeviceUseStatement in the case where a patient uses a privately owned Device instead of an SSL provisioned device.
The official URL for this profile is:
http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement
This profile builds on DeviceUseStatement.
This profile was published on Wed May 29 18:05:58 UTC 2019 as a draft by ehealth.sundhed.dk.
Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
This structure is derived from DeviceUseStatement
Summary
Mandatory: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
This structure is derived from DeviceUseStatement
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseStatement | 0..* | A record of a device being used by a patient. | ||
extension | 0..* | Extension | Slice: Unordered, Open by value:url | |
extension | 1..1 | ?? [CanonicalType[http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context]] | The careplan context for the device use URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context | |
subject | 1..1 | Reference(eHealth Patient) {r} | ||
source | 0..1 | Reference(eHealth Patient | eHealth Practitioner | eHealth RelatedPerson) {r} | ||
device | 1..1 | Reference(eHealth Device) {r} | ||
indication | 0..* | CodeableConcept | Binding: DeviceUseReason (required) | |
coding | 0..* | Coding | Binding: DeviceUseReason (required) | |
note | 0..* | Annotation | Additional details (comments, instructions) | |
author[x] | 0..1 | Reference(eHealth Practitioner | eHealth Patient | eHealth RelatedPerson) {r}, string | ||
Documentation for this format |
This structure is derived from DeviceUseStatement
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseStatement | I | 0..* | A record of a device being used by a patient. | |
id | Σ | 0..1 | id | Logical id of this artifact |
meta | Σ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: Common Languages (extensible) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
extension | 1..1 | ?? [CanonicalType[http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context]] | The careplan context for the device use URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | 0..* | Identifier | External identifier for this record | |
status | ?!Σ | 1..1 | code | active | completed | entered-in-error + Binding: DeviceUseStatementStatus (required) |
subject | 1..1 | Reference(eHealth Patient) {r} | Patient using device | |
whenUsed | 0..1 | Period | Period device was used | |
timing[x] | 0..1 | Timing, Period, dateTime | How often the device was used | |
recordedOn | 0..1 | dateTime | When statement was recorded | |
source | 0..1 | Reference(eHealth Patient | eHealth Practitioner | eHealth RelatedPerson) {r} | Who made the statement | |
device | 1..1 | Reference(eHealth Device) {r} | Reference to device used | |
indication | 0..* | CodeableConcept | Why device was used Binding: DeviceUseReason (required) | |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
coding | Σ | 0..* | Coding | Code defined by a terminology system Binding: DeviceUseReason (required) |
text | Σ | 0..1 | string | Plain text representation of the concept |
bodySite | 0..1 | CodeableConcept | Target body site Binding: SNOMED CT Body Structures (example) | |
note | 0..* | Annotation | Additional details (comments, instructions) | |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
author[x] | Σ | 0..1 | Reference(eHealth Practitioner | eHealth Patient | eHealth RelatedPerson) {r}, string | Individual responsible for the annotation |
time | Σ | 0..1 | dateTime | When the annotation was made |
text | 1..1 | string | The annotation - text content | |
Documentation for this format |
This structure is derived from DeviceUseStatement
Summary
Mandatory: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Differential View
This structure is derived from DeviceUseStatement
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseStatement | 0..* | A record of a device being used by a patient. | ||
extension | 0..* | Extension | Slice: Unordered, Open by value:url | |
extension | 1..1 | ?? [CanonicalType[http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context]] | The careplan context for the device use URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context | |
subject | 1..1 | Reference(eHealth Patient) {r} | ||
source | 0..1 | Reference(eHealth Patient | eHealth Practitioner | eHealth RelatedPerson) {r} | ||
device | 1..1 | Reference(eHealth Device) {r} | ||
indication | 0..* | CodeableConcept | Binding: DeviceUseReason (required) | |
coding | 0..* | Coding | Binding: DeviceUseReason (required) | |
note | 0..* | Annotation | Additional details (comments, instructions) | |
author[x] | 0..1 | Reference(eHealth Practitioner | eHealth Patient | eHealth RelatedPerson) {r}, string | ||
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseStatement | I | 0..* | A record of a device being used by a patient. | |
id | Σ | 0..1 | id | Logical id of this artifact |
meta | Σ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: Common Languages (extensible) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
extension | 1..1 | ?? [CanonicalType[http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context]] | The careplan context for the device use URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | 0..* | Identifier | External identifier for this record | |
status | ?!Σ | 1..1 | code | active | completed | entered-in-error + Binding: DeviceUseStatementStatus (required) |
subject | 1..1 | Reference(eHealth Patient) {r} | Patient using device | |
whenUsed | 0..1 | Period | Period device was used | |
timing[x] | 0..1 | Timing, Period, dateTime | How often the device was used | |
recordedOn | 0..1 | dateTime | When statement was recorded | |
source | 0..1 | Reference(eHealth Patient | eHealth Practitioner | eHealth RelatedPerson) {r} | Who made the statement | |
device | 1..1 | Reference(eHealth Device) {r} | Reference to device used | |
indication | 0..* | CodeableConcept | Why device was used Binding: DeviceUseReason (required) | |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
coding | Σ | 0..* | Coding | Code defined by a terminology system Binding: DeviceUseReason (required) |
text | Σ | 0..1 | string | Plain text representation of the concept |
bodySite | 0..1 | CodeableConcept | Target body site Binding: SNOMED CT Body Structures (example) | |
note | 0..* | Annotation | Additional details (comments, instructions) | |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
author[x] | Σ | 0..1 | Reference(eHealth Practitioner | eHealth Patient | eHealth RelatedPerson) {r}, string | Individual responsible for the annotation |
time | Σ | 0..1 | dateTime | When the annotation was made |
text | 1..1 | string | The annotation - text content | |
Documentation for this format |
Path | Name | Conformance | ValueSet |
DeviceUseStatement.language | Common Languages | extensible | Common Languages |
DeviceUseStatement.status | DeviceUseStatementStatus | required | DeviceUseStatementStatus |
DeviceUseStatement.indication | DeviceUseReason | required | DeviceUseReason |
DeviceUseStatement.indication.coding | DeviceUseReason | required | DeviceUseReason |
DeviceUseStatement.bodySite | SNOMED CT Body Structures | example | SNOMED CT Body Structures |
Id | Path | Details | Requirements |
dom-2 | DeviceUseStatement | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-1 | DeviceUseStatement | If the resource is contained in another resource, it SHALL NOT contain any narrative : contained.text.empty() | |
dom-4 | DeviceUseStatement | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-3 | DeviceUseStatement | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource : contained.where(('#'+id in %resource.descendants().reference).not()).empty() |