eHealth Infrastructure
3.0.0 - release

eHealth Infrastructure - Local Development build (v3.0.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

CodeSystem: Device Measuring Quality

Official URL: http://ehealth.sundhed.dk/cs/device-measuring-quality Version: 3.0.0
Active as of 2019-01-29 Computable Name: DeviceMeasuringQuality

Quality codes for qualities with which a device can perform measuring

This Code system is referenced in the content logical definition of the following value sets:

This case-sensitive code system http://ehealth.sundhed.dk/cs/device-measuring-quality defines the following codes in an undefined heirarchy:

LvlCodeDisplayDefinitionDansk (Danish, da)
1none No quality neededQuality value where no derivation rule logic nor values are expectedIngen udstyrskvalitet krævet/ventet
2  unknown Unknown qualityUnknown quality (Unlikely to be adequate if a quality value is expected)Ukendt udstyrskvalitet
3    derivation-error Error in deriving or determining the qualityQuality value could not be derived due to insufficient input, unknown/unavailable logic, or other errorUdstyrskvaliteten kunne ikke bestemmes grundet manglende input, utilgængelig logik, eller anden fejl.
4      normal Normal/neutral device measuring qualityNormal/neutral device measuring qualityNormalt/neutralt udstyrskvalitetsniveau
5        low-precision Low precision/credibility grade device qualityLow precision/credibility grade device quality. Typically such device is not clinical grade.Lav præcision eller pålidelighed
6          low-precision-degraded Degraded quality for low precision/credibility grade deviceDegraded quality for low precision/credibility grade device. Typically such device is not clinical grade.Forringet kvalitet for udstyr med lav præcision eller pålidelighed
7            low-precision-normal Normal/neutral quality for low precision/credibility grade deviceNormal/neutral quality for low precision/credibility grade device. Typically such device is not clinical grade.Normal kvalitet for udstyr med lav præcision eller pålidelighed
8              low-precision-uncalibrated Quality for uncalibrated low precision/credibility grade deviceQuality for uncalibrated low precision/credibility grade device. Typically such device is not clinical grade.Kvalitet for ukalibreret udstyr med lav præcision eller pålidelighed
9                low-precision-calibrated Quality for calibrated low precision/credibility grade deviceQuality for calibrated low precision/credibility grade device. Typically such device is not clinical grade.Kvalitet for kalibreret udstyr med lav præcision eller pålidelighed
10                  high-precision High precision/credibility grade device qualityHigh precision/credibility grade device quality. Typically such device is clinical grade.Høj præcision eller pålidelighed
11                    high-precision-degraded Degraded quality for high precision/credibility grade deviceDegraded quality for high precision/credibility grade device. Typically such device is clinical grade.Forringet kvalitet for udstyr med høj præcision eller pålidelighed
12                      high-precision-normal Normal/neutral quality for high precision/credibility grade deviceNormal/neutral quality for high precision/credibility grade device. Typically such device is clinical grade.Normal kvalitet for udstyr med høj præcision eller pålidelighed
13                        high-precision-uncalibrated Quality for uncalibrated high precision/credibility grade deviceQuality for uncalibrated high precision/credibility grade device. Typically such device is clinical grade.Kvalitet for ukalibreret udstyr med høj præcision eller pålidelighed
14                          high-precision-calibrated Quality for calibrated high precision/credibility grade deviceQuality for calibrated high precision/credibility grade device. Typically such device is clinical grade.Kvalitet for kalibreret udstyr med høj præcision eller pålidelighed
1TBD Example value - Under constructionExample value - Under construction