eHealth Infrastructure
3.0.0 - release

eHealth Infrastructure - Local Development build (v3.0.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: Device Measuring Quality - TTL Representation

Active as of 2019-01-29

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CodeSystem ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "ehealth-device-measuring-quality"] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>This case-sensitive code system <code>http://ehealth.sundhed.dk/cs/device-measuring-quality</code> defines the following codes in an undefined heirarchy:</p><table class=\"codes\"><tr><td><b>Lvl</b></td><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>Dansk (Danish, da)</b></td></tr><tr><td>1</td><td style=\"white-space:nowrap\">none<a name=\"ehealth-device-measuring-quality-none\"> </a></td><td>No quality needed</td><td>Quality value where no derivation rule logic nor values are expected</td><td>Ingen udstyrskvalitet krævet/ventet</td></tr><tr><td>2</td><td style=\"white-space:nowrap\">  unknown<a name=\"ehealth-device-measuring-quality-unknown\"> </a></td><td>Unknown quality</td><td>Unknown quality (Unlikely to be adequate if a quality value is expected)</td><td>Ukendt udstyrskvalitet</td></tr><tr><td>3</td><td style=\"white-space:nowrap\">    derivation-error<a name=\"ehealth-device-measuring-quality-derivation-error\"> </a></td><td>Error in deriving or determining the quality</td><td>Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error</td><td>Udstyrskvaliteten kunne ikke bestemmes grundet manglende input, utilgængelig logik, eller anden fejl.</td></tr><tr><td>4</td><td style=\"white-space:nowrap\">      normal<a name=\"ehealth-device-measuring-quality-normal\"> </a></td><td>Normal/neutral device measuring quality</td><td>Normal/neutral device measuring quality</td><td>Normalt/neutralt udstyrskvalitetsniveau</td></tr><tr><td>5</td><td style=\"white-space:nowrap\">        low-precision<a name=\"ehealth-device-measuring-quality-low-precision\"> </a></td><td>Low precision/credibility grade device quality</td><td>Low precision/credibility grade device quality. Typically such device is not clinical grade.</td><td>Lav præcision eller pålidelighed</td></tr><tr><td>6</td><td style=\"white-space:nowrap\">          low-precision-degraded<a name=\"ehealth-device-measuring-quality-low-precision-degraded\"> </a></td><td>Degraded quality for low precision/credibility grade device</td><td>Degraded quality for low precision/credibility grade device. Typically such device is not clinical grade.</td><td>Forringet kvalitet for udstyr med lav præcision eller pålidelighed</td></tr><tr><td>7</td><td style=\"white-space:nowrap\">            low-precision-normal<a name=\"ehealth-device-measuring-quality-low-precision-normal\"> </a></td><td>Normal/neutral quality for low precision/credibility grade device</td><td>Normal/neutral quality for low precision/credibility grade device. Typically such device is not clinical grade.</td><td>Normal kvalitet for udstyr med lav præcision eller pålidelighed</td></tr><tr><td>8</td><td style=\"white-space:nowrap\">              low-precision-uncalibrated<a name=\"ehealth-device-measuring-quality-low-precision-uncalibrated\"> </a></td><td>Quality for uncalibrated low precision/credibility grade device</td><td>Quality for uncalibrated low precision/credibility grade device. Typically such device is not clinical grade.</td><td>Kvalitet for ukalibreret udstyr med lav præcision eller pålidelighed</td></tr><tr><td>9</td><td style=\"white-space:nowrap\">                low-precision-calibrated<a name=\"ehealth-device-measuring-quality-low-precision-calibrated\"> </a></td><td>Quality for calibrated low precision/credibility grade device</td><td>Quality for calibrated low precision/credibility grade device. Typically such device is not clinical grade.</td><td>Kvalitet for kalibreret udstyr med lav præcision eller pålidelighed</td></tr><tr><td>10</td><td style=\"white-space:nowrap\">                  high-precision<a name=\"ehealth-device-measuring-quality-high-precision\"> </a></td><td>High precision/credibility grade device quality</td><td>High precision/credibility grade device quality. Typically such device is clinical grade.</td><td>Høj præcision eller pålidelighed</td></tr><tr><td>11</td><td style=\"white-space:nowrap\">                    high-precision-degraded<a name=\"ehealth-device-measuring-quality-high-precision-degraded\"> </a></td><td>Degraded quality for high precision/credibility grade device</td><td>Degraded quality for high precision/credibility grade device. Typically such device is clinical grade.</td><td>Forringet kvalitet for udstyr med høj præcision eller pålidelighed</td></tr><tr><td>12</td><td style=\"white-space:nowrap\">                      high-precision-normal<a name=\"ehealth-device-measuring-quality-high-precision-normal\"> </a></td><td>Normal/neutral quality for high precision/credibility grade device</td><td>Normal/neutral quality for high precision/credibility grade device. Typically such device is clinical grade.</td><td>Normal kvalitet for udstyr med høj præcision eller pålidelighed</td></tr><tr><td>13</td><td style=\"white-space:nowrap\">                        high-precision-uncalibrated<a name=\"ehealth-device-measuring-quality-high-precision-uncalibrated\"> </a></td><td>Quality for uncalibrated high precision/credibility grade device</td><td>Quality for uncalibrated high precision/credibility grade device. Typically such device is clinical grade.</td><td>Kvalitet for ukalibreret udstyr med høj præcision eller pålidelighed</td></tr><tr><td>14</td><td style=\"white-space:nowrap\">                          high-precision-calibrated<a name=\"ehealth-device-measuring-quality-high-precision-calibrated\"> </a></td><td>Quality for calibrated high precision/credibility grade device</td><td>Quality for calibrated high precision/credibility grade device. Typically such device is clinical grade.</td><td>Kvalitet for kalibreret udstyr med høj præcision eller pålidelighed</td></tr><tr><td>1</td><td style=\"white-space:nowrap\">TBD<a name=\"ehealth-device-measuring-quality-TBD\"> </a></td><td>Example value - Under construction</td><td>Example value - Under construction</td><td/></tr></table></div>"
  ] ; # 
  fhir:url [ fhir:v "http://ehealth.sundhed.dk/cs/device-measuring-quality"^^xsd:anyURI] ; # 
  fhir:version [ fhir:v "3.0.0"] ; # 
  fhir:name [ fhir:v "DeviceMeasuringQuality"] ; # 
  fhir:title [ fhir:v "Device Measuring Quality"] ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:experimental [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:date [ fhir:v "2019-01-29T00:00:00+00:00"^^xsd:dateTime] ; # 
  fhir:publisher [ fhir:v "Den telemedicinske infrastruktur (eHealth Infrastructure)"] ; # 
  fhir:contact ( [
fhir:name [ fhir:v "Den telemedicinske infrastruktur (eHealth Infrastructure)" ] ;
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "http://ehealth.sundhed.dk" ]     ] )
  ] ) ; # 
  fhir:description [ fhir:v "Quality codes for qualities with which a device can perform measuring"] ; # 
  fhir:caseSensitive [ fhir:v "true"^^xsd:boolean] ; # 
  fhir:content [ fhir:v "complete"] ; # 
  fhir:concept ( [
fhir:code [ fhir:v "none" ] ;
fhir:display [ fhir:v "No quality needed" ] ;
fhir:definition [ fhir:v "Quality value where no derivation rule logic nor values are expected" ] ;
    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Ingen udstyrskvalitet krævet/ventet" ]     ] ) ;
    ( fhir:concept [
fhir:code [ fhir:v "unknown" ] ;
fhir:display [ fhir:v "Unknown quality" ] ;
fhir:definition [ fhir:v "Unknown quality (Unlikely to be adequate if a quality value is expected)" ] ;
      ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Ukendt udstyrskvalitet" ]       ] ) ;
      ( fhir:concept [
fhir:code [ fhir:v "derivation-error" ] ;
fhir:display [ fhir:v "Error in deriving or determining the quality" ] ;
fhir:definition [ fhir:v "Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error" ] ;
        ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Udstyrskvaliteten kunne ikke bestemmes grundet manglende input, utilgængelig logik, eller anden fejl." ]         ] ) ;
        ( fhir:concept [
fhir:code [ fhir:v "normal" ] ;
fhir:display [ fhir:v "Normal/neutral device measuring quality" ] ;
fhir:definition [ fhir:v "Normal/neutral device measuring quality" ] ;
          ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Normalt/neutralt udstyrskvalitetsniveau" ]           ] ) ;
          ( fhir:concept [
fhir:code [ fhir:v "low-precision" ] ;
fhir:display [ fhir:v "Low precision/credibility grade device quality" ] ;
fhir:definition [ fhir:v "Low precision/credibility grade device quality. Typically such device is not clinical grade." ] ;
            ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Lav præcision eller pålidelighed" ]             ] ) ;
            ( fhir:concept [
fhir:code [ fhir:v "low-precision-degraded" ] ;
fhir:display [ fhir:v "Degraded quality for low precision/credibility grade device" ] ;
fhir:definition [ fhir:v "Degraded quality for low precision/credibility grade device. Typically such device is not clinical grade." ] ;
              ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Forringet kvalitet for udstyr med lav præcision eller pålidelighed" ]               ] ) ;
              ( fhir:concept [
fhir:code [ fhir:v "low-precision-normal" ] ;
fhir:display [ fhir:v "Normal/neutral quality for low precision/credibility grade device" ] ;
fhir:definition [ fhir:v "Normal/neutral quality for low precision/credibility grade device. Typically such device is not clinical grade." ] ;
                ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Normal kvalitet for udstyr med lav præcision eller pålidelighed" ]                 ] ) ;
                ( fhir:concept [
fhir:code [ fhir:v "low-precision-uncalibrated" ] ;
fhir:display [ fhir:v "Quality for uncalibrated low precision/credibility grade device" ] ;
fhir:definition [ fhir:v "Quality for uncalibrated low precision/credibility grade device. Typically such device is not clinical grade." ] ;
                  ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Kvalitet for ukalibreret udstyr med lav præcision eller pålidelighed" ]                   ] ) ;
                  ( fhir:concept [
fhir:code [ fhir:v "low-precision-calibrated" ] ;
fhir:display [ fhir:v "Quality for calibrated low precision/credibility grade device" ] ;
fhir:definition [ fhir:v "Quality for calibrated low precision/credibility grade device. Typically such device is not clinical grade." ] ;
                    ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Kvalitet for kalibreret udstyr med lav præcision eller pålidelighed" ]                     ] ) ;
                    ( fhir:concept [
fhir:code [ fhir:v "high-precision" ] ;
fhir:display [ fhir:v "High precision/credibility grade device quality" ] ;
fhir:definition [ fhir:v "High precision/credibility grade device quality. Typically such device is clinical grade." ] ;
                      ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Høj præcision eller pålidelighed" ]                       ] ) ;
                      ( fhir:concept [
fhir:code [ fhir:v "high-precision-degraded" ] ;
fhir:display [ fhir:v "Degraded quality for high precision/credibility grade device" ] ;
fhir:definition [ fhir:v "Degraded quality for high precision/credibility grade device. Typically such device is clinical grade." ] ;
                        ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Forringet kvalitet for udstyr med høj præcision eller pålidelighed" ]                         ] ) ;
                        ( fhir:concept [
fhir:code [ fhir:v "high-precision-normal" ] ;
fhir:display [ fhir:v "Normal/neutral quality for high precision/credibility grade device" ] ;
fhir:definition [ fhir:v "Normal/neutral quality for high precision/credibility grade device. Typically such device is clinical grade." ] ;
                          ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Normal kvalitet for udstyr med høj præcision eller pålidelighed" ]                           ] ) ;
                          ( fhir:concept [
fhir:code [ fhir:v "high-precision-uncalibrated" ] ;
fhir:display [ fhir:v "Quality for uncalibrated high precision/credibility grade device" ] ;
fhir:definition [ fhir:v "Quality for uncalibrated high precision/credibility grade device. Typically such device is clinical grade." ] ;
                            ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Kvalitet for ukalibreret udstyr med høj præcision eller pålidelighed" ]                             ] ) ;
                            ( fhir:concept [
fhir:code [ fhir:v "high-precision-calibrated" ] ;
fhir:display [ fhir:v "Quality for calibrated high precision/credibility grade device" ] ;
fhir:definition [ fhir:v "Quality for calibrated high precision/credibility grade device. Typically such device is clinical grade." ] ;
                              ( fhir:designation [
fhir:language [ fhir:v "da" ] ;
fhir:value [ fhir:v "Kvalitet for kalibreret udstyr med høj præcision eller pålidelighed" ]                               ] )                             ] )                           ] )                         ] )                       ] )                     ] )                   ] )                 ] )               ] )             ] )           ] )         ] )       ] )     ] )
  ] [
fhir:code [ fhir:v "TBD" ] ;
fhir:display [ fhir:v "Example value - Under construction" ] ;
fhir:definition [ fhir:v "Example value - Under construction" ] ;
    ( fhir:property [
fhir:code [ fhir:v "deprecated" ] ;
fhir:value [ fhir:v "2020-02-03"^^xsd:date ]     ] )
  ] ) . #