"resourceType" : "CodeSystem",
"id" : "ehealth-device-measuring-quality",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>This code system http://ehealth.sundhed.dk/cs/device-measuring-quality defines the following codes:</p><table class=\"codes\"><tr><td><b>Lvl</b></td><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td>1</td><td style=\"white-space:nowrap\">none<a name=\"ehealth-device-measuring-quality-none\"> </a></td><td>No quality needed</td><td>Quality value where no derivation rule logic nor values are expected</td></tr><tr><td>2</td><td style=\"white-space:nowrap\"> unknown<a name=\"ehealth-device-measuring-quality-unknown\"> </a></td><td>Unknown quality</td><td>Unknown quality (Unlikely to be adequate if a quality value is expected)</td></tr><tr><td>3</td><td style=\"white-space:nowrap\"> derivation-error<a name=\"ehealth-device-measuring-quality-derivation-error\"> </a></td><td>Error in deriving or determining the quality</td><td>Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error</td></tr><tr><td>4</td><td style=\"white-space:nowrap\"> normal<a name=\"ehealth-device-measuring-quality-normal\"> </a></td><td>Normal/neutral device measuring quality</td><td>Normal/neutral device measuring quality</td></tr><tr><td>5</td><td style=\"white-space:nowrap\"> low-precision<a name=\"ehealth-device-measuring-quality-low-precision\"> </a></td><td>Low precision/credibility grade device quality</td><td>Low precision/credibility grade device quality. Typically such device is not clinical grade.</td></tr><tr><td>6</td><td style=\"white-space:nowrap\"> low-precision-degraded<a name=\"ehealth-device-measuring-quality-low-precision-degraded\"> </a></td><td>Degraded quality for low precision/credibility grade device</td><td>Degraded quality for low precision/credibility grade device. Typically such device is not clinical grade.</td></tr><tr><td>7</td><td style=\"white-space:nowrap\"> low-precision-normal<a name=\"ehealth-device-measuring-quality-low-precision-normal\"> </a></td><td>Normal/neutral quality for low precision/credibility grade device</td><td>Normal/neutral quality for low precision/credibility grade device. Typically such device is not clinical grade.</td></tr><tr><td>8</td><td style=\"white-space:nowrap\"> low-precision-uncalibrated<a name=\"ehealth-device-measuring-quality-low-precision-uncalibrated\"> </a></td><td>Quality for uncalibrated low precision/credibility grade device</td><td>Quality for uncalibrated low precision/credibility grade device. Typically such device is not clinical grade.</td></tr><tr><td>9</td><td style=\"white-space:nowrap\"> low-precision-calibrated<a name=\"ehealth-device-measuring-quality-low-precision-calibrated\"> </a></td><td>Quality for calibrated low precision/credibility grade device</td><td>Quality for calibrated low precision/credibility grade device. Typically such device is not clinical grade.</td></tr><tr><td>10</td><td style=\"white-space:nowrap\"> high-precision<a name=\"ehealth-device-measuring-quality-high-precision\"> </a></td><td>High precision/credibility grade device quality</td><td>High precision/credibility grade device quality. Typically such device is clinical grade.</td></tr><tr><td>11</td><td style=\"white-space:nowrap\"> high-precision-degraded<a name=\"ehealth-device-measuring-quality-high-precision-degraded\"> </a></td><td>Degraded quality for high precision/credibility grade device</td><td>Degraded quality for high precision/credibility grade device. Typically such device is clinical grade.</td></tr><tr><td>12</td><td style=\"white-space:nowrap\"> high-precision-normal<a name=\"ehealth-device-measuring-quality-high-precision-normal\"> </a></td><td>Normal/neutral quality for high precision/credibility grade device</td><td>Normal/neutral quality for high precision/credibility grade device. Typically such device is clinical grade.</td></tr><tr><td>13</td><td style=\"white-space:nowrap\"> high-precision-uncalibrated<a name=\"ehealth-device-measuring-quality-high-precision-uncalibrated\"> </a></td><td>Quality for uncalibrated high precision/credibility grade device</td><td>Quality for uncalibrated high precision/credibility grade device. Typically such device is clinical grade.</td></tr><tr><td>14</td><td style=\"white-space:nowrap\"> high-precision-calibrated<a name=\"ehealth-device-measuring-quality-high-precision-calibrated\"> </a></td><td>Quality for calibrated high precision/credibility grade device</td><td>Quality for calibrated high precision/credibility grade device. Typically such device is clinical grade.</td></tr><tr><td>1</td><td style=\"white-space:nowrap\">TBD<a name=\"ehealth-device-measuring-quality-TBD\"> </a></td><td>Example value - Under construction</td><td>Example value - Under construction</td></tr></table><p><b>Additional Language Displays</b></p><table class=\"codes\"><tr><td><b>Code</b></td><td><b>Dansk (Danish, da)</b></td></tr><tr><td>none</td><td>Ingen udstyrskvalitet krævet/ventet</td></tr><tr><td>TBD</td><td></td></tr></table></div>"
},
"url" : "http://ehealth.sundhed.dk/cs/device-measuring-quality",
"version" : "2021.3.0",
"name" : "DeviceMeasuringQuality",
"title" : "Device Measuring Quality",
"status" : "active",
"experimental" : false,
"date" : "2019-01-29T00:00:00+00:00",
"publisher" : "Systematic | Trifork",
"contact" : [
{
"name" : "Systematic | Trifork",
"telecom" : [
{
"system" : "url",
"value" : "http://ehealth.sundhed.dk"
}
]
}
],
"description" : "Quality codes for qualities with which a device can perform measuring",
"caseSensitive" : true,
"content" : "complete",
"concept" : [
{
"code" : "none",
"display" : "No quality needed",
"definition" : "Quality value where no derivation rule logic nor values are expected",
"designation" : [
{
"language" : "da",
"value" : "Ingen udstyrskvalitet krævet/ventet"
}
],
"concept" : [
{
"code" : "unknown",
"display" : "Unknown quality",
"definition" : "Unknown quality (Unlikely to be adequate if a quality value is expected)",
"designation" : [
{
"language" : "da",
"value" : "Ukendt udstyrskvalitet"
}
],
"concept" : [
{
"code" : "derivation-error",
"display" : "Error in deriving or determining the quality",
"definition" : "Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error",
"designation" : [
{
"language" : "da",
"value" : "Udstyrskvaliteten kunne ikke bestemmes grundet manglende input, utilgængelig logik, eller anden fejl."
}
],
"concept" : [
{
"code" : "normal",
"display" : "Normal/neutral device measuring quality",
"definition" : "Normal/neutral device measuring quality",
"designation" : [
{
"language" : "da",
"value" : "Normalt/neutralt udstyrskvalitetsniveau"
}
],
"concept" : [
{
"code" : "low-precision",
"display" : "Low precision/credibility grade device quality",
"definition" : "Low precision/credibility grade device quality. Typically such device is not clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Lav præcision eller pålidelighed"
}
],
"concept" : [
{
"code" : "low-precision-degraded",
"display" : "Degraded quality for low precision/credibility grade device",
"definition" : "Degraded quality for low precision/credibility grade device. Typically such device is not clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Forringet kvalitet for udstyr med lav præcision eller pålidelighed"
}
],
"concept" : [
{
"code" : "low-precision-normal",
"display" : "Normal/neutral quality for low precision/credibility grade device",
"definition" : "Normal/neutral quality for low precision/credibility grade device. Typically such device is not clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Normal kvalitet for udstyr med lav præcision eller pålidelighed"
}
],
"concept" : [
{
"code" : "low-precision-uncalibrated",
"display" : "Quality for uncalibrated low precision/credibility grade device",
"definition" : "Quality for uncalibrated low precision/credibility grade device. Typically such device is not clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Kvalitet for ukalibreret udstyr med lav præcision eller pålidelighed"
}
],
"concept" : [
{
"code" : "low-precision-calibrated",
"display" : "Quality for calibrated low precision/credibility grade device",
"definition" : "Quality for calibrated low precision/credibility grade device. Typically such device is not clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Kvalitet for kalibreret udstyr med lav præcision eller pålidelighed"
}
],
"concept" : [
{
"code" : "high-precision",
"display" : "High precision/credibility grade device quality",
"definition" : "High precision/credibility grade device quality. Typically such device is clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Høj præcision eller pålidelighed"
}
],
"concept" : [
{
"code" : "high-precision-degraded",
"display" : "Degraded quality for high precision/credibility grade device",
"definition" : "Degraded quality for high precision/credibility grade device. Typically such device is clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Forringet kvalitet for udstyr med høj præcision eller pålidelighed"
}
],
"concept" : [
{
"code" : "high-precision-normal",
"display" : "Normal/neutral quality for high precision/credibility grade device",
"definition" : "Normal/neutral quality for high precision/credibility grade device. Typically such device is clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Normal kvalitet for udstyr med høj præcision eller pålidelighed"
}
],
"concept" : [
{
"code" : "high-precision-uncalibrated",
"display" : "Quality for uncalibrated high precision/credibility grade device",
"definition" : "Quality for uncalibrated high precision/credibility grade device. Typically such device is clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Kvalitet for ukalibreret udstyr med høj præcision eller pålidelighed"
}
],
"concept" : [
{
"code" : "high-precision-calibrated",
"display" : "Quality for calibrated high precision/credibility grade device",
"definition" : "Quality for calibrated high precision/credibility grade device. Typically such device is clinical grade.",
"designation" : [
{
"language" : "da",
"value" : "Kvalitet for kalibreret udstyr med høj præcision eller pålidelighed"
}
]
}
]
}
]
}
]
}
]
}
]
}
]
}
]
}
]
}
]
}
]
}
]
}
]
}
]
},
{
"code" : "TBD",
"display" : "Example value - Under construction",
"definition" : "Example value - Under construction",
"property" : [
{
"code" : "deprecated",
"valueDateTime" : "2020-02-03"
}
]
}
]
}