The following list contains the error messages that are defined for the eHealth Infrastructure. The error messages are grouped by profile and follows the pattern <PROFILENAME>_<OPERATION>_<ERROR>. The pattern is used to determine which operation can result in the specific error. Note that general errors follows the pattern GENERAL_<ERROR>.
If a requests result in an error, the error message can be obtained from the diagnostics element for the specific entry in the returned issue list:
{
"resourceType": "OperationOutcome",
...
"issue": [
{
"severity": "error",
"code": "processing",
"diagnostics": "Update is only allowed for PlanDefinition with status: DRAFT or ACTIVE."
}
]
}
GENERAL_RESOURCE_NOT_FOUND: Resource %s with id %s is not found.
GENERAL_SUBJECT_AND_CONTEXT_NOT_PROVIDED: At least one of subject and context must be provided.
GENERAL_VALIDATION_ERROR: Validation error: %s
GENERAL_EXPORT_FAILED: Export resource has failed.
ACTIVITYDEFINITION_UPDATE_ALLOWED_FOR_STATUS: Update is only allowed for ActivityDefinition with status: %s or %s.
ACTIVITYDEFINITION_UPDATE_TO_NOT_ALLOWED_STATE: Update is not allowed for ActivityDefinition with %s status to different than %s status.
ASSEMBLER_QRD_COMPOSITION_MISSING_DOCUMENT_REFERENCE: eHealthComposition related to questionnaire is missing eHealthDocumentReference
ASSEMBLER_QRD_INVALID_QUESTIONNAIRE_RELATED_COMPOSITION: There must be just 1 eHealthComposition related to eHealthQuestionnaire
ASSEMBLER_APD_MISSING_SUPPORTING_INFORMATION: Appointment must have supportingInformation
ASSEMBLER_APD_MISSING_PATIENT_PARTICIPANT: Appointment must have at least one Patient participant
ASSEMBLER_APD_MISSING_RESPONSIBLE_ORGANIZATION: Appointment must have responsible-organization
ASSEMBLER_APD_MISSING_PERFORMER: Appointment must have performer
ASSEMBLER_APD_MISSING_RESPONSIBLE_PRACTITIONER: Appointment must have responsible Practitioner
CAREPLAN_APPLY_NO_PLANDEFINITION: There is no PlanDefinition with id %s
CAREPLAN_APPLY_NOT_ACTIVE_PLANDEFINITION: The apply operation can only be performed on Plandefinitions with status “active”
CAREPLAN_APPLY_EPISODE_OF_CARE_REFERENCE_NOT_SPECIFIED: EpisodeOfCare reference must be specified
CAREPLAN_APPLY_PLAN_DEFINITION_REFERENCE_NOT_SPECIFIED: PlanDefinition reference must be specified
CAREPLAN_APPLY_CAN_NOT_FIND_ACTIVITY_DEFINITION: Can not find activity definition with id :%s
CAREPLAN_NOT_FOUND: CarePlan is not found.
CAREPLAN_SEARCH_SUBJECT_CONTEXT_OR_RESPONSIBLE_ACTOR_IS_NOT_SPECIFIED: At least subject, context or responsible actor must be specified
CARETEAM_GENERAL_EXTERNAL_SECURITY_TOKEN_CARETEAM_IDENTIFIER_SYSTEM_IS_MISSING: The CareTeam must contain an identifier using system “urn:ietf:rfc:3986”COMMUNICATIONREQUEST_CONTEXT_NOT_MATCHING_SERVICEREQUEST: The context for the CommunicationRequest: %s does not match the context of the referenced ServiceRequest: %s
COMMUNICATIONREQUEST_SUBJECT_NOT_MATCHING_RECIPIENT: Patient recipient: %s does not match the subject: %s
COMMUNICATIONREQUEST_SUBJECT_NOT_MATCHING_SERVICEREQUEST: The subject for the CommunicationRequest: %s does not match the subject of the referenced ServiceRequest: %s
COMMUNICATIONREQUEST_EXCACTLY_ONE_RECIPIENT_SEARCHPRARAM: Excactly one recipient search parameter required
CONTEXT_VALIDATION_EPISODEOFCARE_EXCEPTION: Episode of care does not match the security token contextDEFINITION_WITHOUT_SELF_TREATMENT_TOPIC: %s has to be with self-treatment topicDEVICE_WRITE_WRONG_PATIENT_CONTEXT: User with patient context can only read devices that has been issued to the patient
DEVICE_WRITE_WRONG_ORGANIZATION_CONTEXT: User must be logged into the organization that is the owner of the device
DEVICE_METRIC_WRITE_WRONG_ORGANIZATION_CONTEXT: User must be logged into the organization that is the owner of the device
DEVICE_USE_STATEMENT_WRITE_WRONG_ORGANIZATION_CONTEXT: User must be logged into the organization that is the owner of the device
DOCUMENT_QUERY_SOR_ORGANIZATION_REQUIRED: Security token organization context must be a SOR organization for query
DOCUMENT_QUERY_XDS_ERROR: The following errors where received from Document Sharing
DOCUMENT_QUERY_DOCUMENT_URL_NOT_CORRECT_FORMAT: Url doesn’t have expected format:
DOCUMENTREFERENCE_SUBJECT_REFER_TO_PATIENT: It is not possible to set a patient as a subject for a Document referenceEPISODEOFCARE_CREATE_WRONG_EOC_COUNT: Bundle has to contain only one Episode of Care
EPISODEOFCARE_CREATE_UNSUPPORTED_RESOURCE_TYPE: Bundle contains unsupported resource type
EPISODEOFCARE_CREATE_INCORRECT_PROVENANCE_TARGET: Provenance has incorrect target
EPISODEOFCARE_CREATE_NO_REQUIRED_PROVENANCE_POLICIES: No provenance with required policies
EPISODEOFCARE_CREATE_INCORRECT_CONDITION_SUBJECT: EpisodeOfCare and Condition doesn’t point to the same Patient
EPISODEOFCARE_PATCH_NO_CONSENT: No valid Episode Of Care related consent
EPISODEOFCARE_CREATE_PATIENT_MUST_BE_ACTIVE_AND_NOT_DECEASED: Patient.active must be true and Patient.deceased must be false to create episode of care
EPISODEOFCARE_CREATE_STATUS_HISTORY_NOT_EMPTY: It is not allowed to fill status history manually
EPISODEOFCARE_CREATE_EPISODE_OF_CARE_IN_NON_PLANNED_STATUS: It is only possible to create an episode of care in status ‘Planned’
EPISODEOFCARE_CREATE_TEAM_HISTORY_NOT_EMPTY: It is not allowed to fill team history manually
EPISODEOFCARE_CREATE_PATIENT_DOESNT_MATCH_CONTEXT: Episode of care patient doesn’t match to the context
EPISODEOFCARE_IS_CONTEXT_ALLOWED_MATCH_NOT_FOUND: It is not possible to set the Episode Of Care as a context
LIBRARY_EVALUATE_NO_INPUT_PARAMETER: An input parameter of type Parameters should be provided.
LIBRARY_EVALUATE_INCORRECT_INPUT_PARAMETER: Input parameter ‘parameters’ should contain exactly one resource of type QuestionnaireResponse, Observation or Media.
LIBRARY_EVALUATE_NO_RULE_DEFINED: Library with id %s do not contain a rule to use for evaluation.
LIBRARY_EVALUATE_NO_CAREPLAN_REFERENCING_PROVIDED_PROCEDUREQUEST: CarePlan with reference to ServiceRequest with id %s is not found.
LIBRARY_EVALUATE_RULE_SYNTAX_ERRORS: Syntax for rule is invalid. %s
LIBRARY_EVALUATE_OUTPUT_PARAMETER_NOT_SUPPORTED: Output parameter of type %s is not supported.
LIBRARY_EVALUATE_INPUT_PARAMETER_NOT_SUPPORTED: Input parameter of type %s is not supported.
LIBRARY_EVALUATE_UNEXPECTED_LIBRARY: Evaluate is invoked on Library with id %s. This Library is not the expected Library referenced by the ActivityDefinition.
LIBRARY_EVALUATE_UNABLE_TO_RESOLVE_RESOURCE: Not able to resolve %s when input is of type %s.
LIBRARY_EVALUATE_DURATION_UNIT_CODE_UNKNOWN: Unsupported code %s for Duration.code. Duration.code should be a valid UCUM code. Supported codes are (‘s’, ‘min’, ‘h’, ‘d’, ‘wk’, ‘mo’, ‘a’).
LIBRARY_EVALUATE_LOGIC_RULE_INVALID_INPUT: Error evaluating logic rule. Category: %s, Focus: %s, RuleDescription: %s
LIBRARY_IDENTIFIER_UPDATE_RESTRICTED: Validation error: attempt to update Library Identifiers list.
LIBRARY_UNKNOWN_IDENTIFIER: Unable to find unique Library with identifier: %s. Number of search results: %s
LIBRARY_MISSING_IDENTIFIER: Library %s does not have identifier of type: %s
MEASUREMENT_SEARCHMEASUREMENT_PERIOD_NOT_SPECIFIED: Period must be specified
MEASUREMENT_SEARCHMEASUREMENT_PATIENT_AND_EPISODE_NOT_SPECIFIED: At least patient or episodeOfCare must be specified
MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_PATIENT_REFERENCE: Unsupported patient reference
MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_EPISODEOFCARE_REFERENCE: Unsupported episodeOfCare reference
MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_DEVICE_REFERENCE: Unsupported device reference
MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_BASEDON_REFERENCE: Unsupported based-on reference: %s
MEASUREMENT_SEARCHMEASUREMENT_REFERENCED_RESOURCE_NOT_FOUND: Referenced resource not found: %s
MEASUREMENT_SUBMITMEASUREMENT_INVALID_OBSERVATION_CODE: Observation.code does not match the code of the referenced ServiceRequest with id %s.
MEASUREMENT_SUBMITMEASUREMENT_INVALID_QUESTIONNAIRE_REFERENCE: Questionnaire reference with id %s is unexpected. Expected questionnaire reference to match questionnaire reference of related ActivityDefinition with id %s.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_SHOULD_REFERENCE_PATIENT: Input resources of type EHealthObservation, EHealthMedia and EHealthQuestionnaireResponse should reference a patient.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_SHOULD_REFERENCE_EPISODEOFCARE: Input resources of type EHealthObservation, EHealthMedia and EHealthQuestionnaireResponse should reference an episode of care.
MEASUREMENT_SUBMITMEASUREMENT_EMPTY_INPUT_BUNDLE: The input bundle does not contain any resources.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_BUNDLE_CONTAINS_NONE_OF_EXPECTED_RESOURCES: The input bundle does not contain any resources of type EHealthObservation, EHealthMedia, EHealthQuestionnaireResponse.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_BUNDLE_CONTAINS_INVALID_RESOURCES: The input bundle contains resources which are not of type EHealthObservation, EHealthMedia, EHealthQuestionnaireResponse or EHealthProvenance.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_INVALID_POLICY: Submitted provenances should use the policy ‘Reuse of measurement chosen by citizen’
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_REFERENCE_MISSING: EHealthProvenance resource is referencing %s but it is not provided as part of the input.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_NOT_SINGLE_TARGET: Provenance.target should have exactly one reference.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_BE_SAME_TYPE: Provenance.target and Provenance.entity should be of same type.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_REFERENCE_SAME_PATIENT: Provenance.target and Provenance.entity should reference the same patient
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_USE_SAME_DATE: Provenance.target and Provenance.entity should use the same date.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_ENTITY_IS_REUSING: Provenance.entity is reusing another measurement and thus can not be used for reuse.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_INVALID: %s is invalid.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_NOT_SINGLE_ENTITY: Provenance.entity should have exactly one reference.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_FOR_DIFFERENT_PATIENTS: The resources provided are for different patients.
MEASUREMENT_SUBMITMEASUREMENT_INPUT_NOT_PART_OF_SAME_EPISODEOFCARE: The resources provided are not all part of the same episode of care.
MEASUREMENT_SUBMITMEASUREMENT_PROCEDURE_REQUEST_IS_NOT_ACTIVE: Procedure request with id:[%s] is not active.
MEASUREMENT_SUBMITMEASUREMENT_ACTIVITYDEFINITION_MISSING_QUESTIONNAIRE_REFERENCE: ActivityDefinition with id %s does not contain a relatedArtifact with a Questionnaire reference
MEASUREMENT_SUBMITMEASUREMENT_DIFFERENT_PATIENT_REFERENCE: The patient referenced by the EpisodeOfCare is different than the patient referenced by the provided resources
MEASUREMENT_SUBMITMEASUREMENT_REUSE_NOT_ALLOWED: Reuse of resource with id %s is not allowed.
MEASUREMENT_SUBMITMEASUREMENT_ASSOCIATED_QUALITY_NOT_PRESENT: Associated quality %s is not present on submitted resource. Reuse of resource is not allowed.
MEASUREMENT_SUBMITMEASUREMENT_QUALITY_IS_NOT_SUBSUMED: Quality %s does not subsume %s. Reuse of resource is not allowed.
MEASUREMENT_SUBMITMEASUREMENT_RESOURCE_TO_OLD_TO_BE_USED_FOR_REUSE: Reuse of resource is not allowed due to the resource being too old.
MEASUREMENT_SUBMITMEASUREMENT_DURATION_UNIT_CODE_UNKNOWN: Unsupported code %s for Duration.code. Duration.code should be a valid UCUM code. Supported codes are (‘s’, ‘min’, ‘h’, ‘d’, ‘wk’, ‘mo’, ‘a’).
MEASUREMENT_SUBMITMEASUREMENT_MORE_THAN_ONE_DEVICE_QUALITY: Only one device quality allowed for each observation/media
MEASUREMENT_SUBMITMEASUREMENT_INVALID_RESOLVED_TIMING: ResolvedTiming must have either type=Resolved and start/end or type=Unresolved/Adhoc and no start/end
MEASUREMENT_GET_DATA_NO_DATA_FOUND: Encrypted media data with id %s was not found
ORGANIZATION_SOURCE_MUST_BE_MANUAL: The operation can only be performed for Organization with source “manual”
ORGANIZATION_IDENTIFIER_MUST_BE_SSL_WHEN_SOURCE_MANUAL: The operation can only be performed for SSL Organizations when the source is “manual”
ORGANIZATION_IDENTIFIER_NOT_UNIQUE: Organization Identifier not unique: %s
ORGANIZATION_IDENTIFIER_SYSTEM_NOT_ALLOWED_FOR_SOURCE_MANUAL: Identifier system is not allowed for Organization with source “manual”
ORGANIZATION_TRAVERSE_TO_SOR_NOT_POSSIBLE: No related SOR organization could be found for: %s
ORGANIZATION_IDENTIFIER_MUST_CONTAIN_AT_LEAST_CVR_FOR_SOURCE_MANUAL: Identifier system CVR required for Organization with source “manual”
ORGANIZATION_UNKNOWN_IDENTIFIER: Unable to find unique Organization with identifier: %s. Number of search results: %s
ORGANIZATION_MISSING_IDENTIFIER: Organization %s does not have identifier of type: %s
PLANDEFINITION_UPDATE_ALLOWED_FOR_STATUS: Update is only allowed for PlanDefinition with status: %s or %s.
PLANDEFINITION_UPDATE_TO_NOT_ALLOWED_STATE: Update is not allowed for PlanDefinition with %s status to different than %s status.
PLANDEFINITION_VALIDATE_MANDATORY_ACTIVITYDEFINITION_OR_SUBPLAN_REFERENCE: At least one activity definition or subplan should be referenced.
PLANDEFINITION_VALIDATE_ALL_REFERENCED_ACTIVITYDEFINITIONS_OR_SUBPLANS_SHOULD_BE_ACTIVE: All referenced activity definitions or subplans should be with state: “active”
PLANDEFINITION_MISSING_RELATED_ACTION: An action points to a non-existing related action
PROVENANCE_NO_READ_PRIVILEGE: User must be logged in with the provenance read privilege
PROVENANCE_NO_SEARCH_PRIVILEGE: User must be logged in with the provenance search privilege
PROVENANCE_SEARCH_DATA_NOT_MATCH_CONTEXT: The target property should match to the episode of care in context
QUESTIONNAIRE_NOT_ALLOWED_TO_UPDATE_IN_STATUS: Update is not allowed for questionnaires with statuses: %s, %s
QUESTIONNAIRE_NOT_ALLOWED_TO_UPDATE_STATUS: Update is not allowed for questionnaires with %s status to different than %s status
QUESTIONNAIRE_NOT_ALLOWED_TO_DELETE_WITH_STATUS: Delete only possible for questionnaires with status: %s
QUESTIONNAIRE_IMAGE_FORMAT_VALIDATION_MESSAGE:
%s Image in questionnaire item with linkID %s and Binary contentType %s does not match any code in ValueSet: %s
QUESTIONNAIRE_IMAGE_SIZE_VALIDATION_MESSAGE:
%s Image in questionnaire item with linkID %s exceeds the maximum size of %s kB
REPORTING_MISSING_INPUT_PARAMETER: Parameter “%s” is mandatory for report “%s”.
REPORTING_REPORT_GENERATION_FAILED: Report generation has failed
REPORTING_SYNCHRONOUS_GENERATION_NOT_ALLOWED: Synchronous generation of the report is not allowed
SECURITY_TOKEN_CONTEXT_NOT_ALLOWED: Security token context not allowed: %s
SECURITY_TOKEN_INSUFFICIENT_PERMISSION: Insufficient permission for %s for %s
SECURITY_USER_NOT_ALLOWED: Resource not allowed for user: %s
SECURITY_TOKEN_CONTEXT_MISSING: Security token context missing for user type: %s
SECURITY_RESOURCE_NOT_MATCHING_TOKEN_CONTEXT: Resource not matching security token context: %s
SECURITY_OPERATION_NOT_ALLOWED_FOR_USER_TYPE: Operation not allowed for user type: %s
SECURITY_SEARCH_PARAM_NOT_MATCHING_TOKEN_CONTEXT: Search parameters not matching security token context: %s
SECURITY_SEARCH_PARAMS_MANDATORY: Search parameters mandatory with current user type and combination of search parameters: %s
STATUS_SCHEDULE_PAUSE_MAX_30_DAYS: A scheduled pause may not last more than 30 days
STATUS_SCHEDULE_IDENTICAL_TIME: Multiple status changes may not be scheduled to be activated simultaneously
TASK_INVESTIGATION_ITEM_REFERENCES_MUST_HAVE_VERSION_AND_VERSIONLESS: Investigation references must have an item with version and one versionless
TASK_RESTRICTION_CATEGORY_NONE_CANT_BE_COMBINED: Restriction category ‘None’ can’t be combined with others
TASK_RESTRICTION_CATEGORY_NOT_MATCHING_TOKEN_CONTEXT: Restriction category ‘%s’ does not match token context
TASK_MEASUREMENT_PROCESSING_FAILED: Measurement processing failed for Provenance %s
TASK_AUTOMATED_PROCESSING_RESOURCE_HANDLER_INVALID_JSON: Unable to parse json string: %s.
TASK_AUTOMATED_PROCESSING_INVALID_INPUT_RESOURCE: Resource of type %s is not a valid input resource.
TASK_AUTOMATED_PROCESSING_MISSING_MEASUREMENT_PROCEDURE_REQUEST: Could not determine if measurement is missing for procedure request: %s.
TASK_AUTOMATED_PROCESSING_FAILING_REQUESTS_JOB_TERMINATED: Limit of %s consecutive failing requests is reached. Scheduled audit job is terminated.
TRANSFORMATION_QFDD_XML_MISSING: Invalid input document reference, it must contain content with data of QFDD xml
TRANSFORMATION_QRD_INVALID_INPUT_PARAMETERS: Input bundle should contain just one EHealthComposition, EHealthQuestionnaireResponse and EHealthQuestionnaire.
TRANSFORMATION_QRD_UNSUPPORTED_QUESTION_TYPE: Unsupported Questionnaire type: %s.
TRANSFORMATION_QRD_INVALID_NUMBER_OF_ANSWERS: QuestionnaireResponse item should contain from %s to %s answers.
TRANSFORMATION_QRD_INVALID_NUMBER_OF_EXTENSIONS: Questionnaire item has invalid extensions.
TRANSFORMATION_QRD_MISSING_IDENTIFIER: Identifier on composition is mandatory
TRANSFORMATION_QRD_XML_MISSING: Invalid input document reference, it must contain content with data of QRD xml
TRANSFORMATION_PHMR_MISSING_RESOURCE: Input bundle missing resource: %s
TRANSFORMATION_PHMR_INVALID_OBSERVATION_CODING: Observation coding system must be urn:oid:1.2.208.176.2.1
TRANSFORMATION_PHMR_INVALID_OBSERVATION_RANGES_CODING: Observation.observationRanges[x].type.coding.system should be http://www.example.com/medcom/message-codes
TRANSFORMATION_PHMR_OBSERVATION_QUANTITY_MISSING: Value should be Quantity type and not null
TRANSFORMATION_PHMR_XML_MISSING: Invalid input document reference, it must contain content with data of PHMR xml
TRANSFORMATION_PHMR_ID_OID_NOT_FOUND: NamingSystem or CodeSystem with url %s is not found.
TRANSFORMATION_HEADER_MISSING_CONFIDENTIALITY_CODE: Composition.confidentiality is mandatory
TRANSFORMATION_HEADER_WRONG_TYPE_COMPOSITION_SUBJECT: Composition.subject should be a Patient
TRANSFORMATION_HEADER_MISSING_CUSTODIAN: Custodian is mandatory for transformation
TRANSFORMATION_HEADER_MISSING_COMPOSITION: Composition expected for transformation is not found
TRANSFORMATION_HEADER_WRONG_TYPE_COMPOSITION_AUTHOR: Composition.author should either be a Patient or Practitioner
TRANSFORMATION_HEADER_MISSING_COMPOSITION_AUTHOR_ORGANIZATION: Composition.authorOrganization is mandatory for transformation
TRANSFORMATION_APD_XML_MISSING: Invalid input document reference, it must contain content with data of APD xml