eHealth Infrastructure
2.5.0 - release

eHealth Infrastructure - Local Development build (v2.5.0). See the Directory of published versions

ValueSet: ClinicalImpression Finding Codes (Experimental)

Official URL: http://ehealth.sundhed.dk/vs/clinicalimpression-finding-codes Version: 2.5.0
Active as of 2019-02-08 Computable Name: ClinicalImpressionFindingCodes

Value set of clinical impression finding codes.

References

Logical Definition (CLD)

This value set includes codes based on the following rules:

 

Expansion

This value set contains 31 concepts

CodeSystemDisplayDefinition
  red-question-answerhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesred question and answer combination

Applied to a single question and answer pair, this indicates a red combination. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates at least one red combination found.

  yellow-question-answerhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesyellow question and answer combination

Applied to a single question and answer pair, this indicates a yellow combination. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates at least one yellow combination found and no red combinations found.

  green-question-answerhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesgreen question and answer combination

Applied to a single question and answer pair, this indicates a green combination. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates at least one green combination found and no red or yellow combinations found.

  no-effective-answer-significancehttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesno effective answer significance for answer and question combination

Applied to a single question and answer pair, this indicates that answer did not meet any answer significance conditions. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates that no answer met the conditions of any answer significance(s) in the related question.

  no-answer-significance-definedhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesno answer significance defined for question(s)

Applied to a single question and answer pair, this indicates that the question did not have any answer significance. Applied as summary to multiple question and answer pairs in a questionnaire response, this indicates that no question had any associated answer significance(s).

  TBDhttp://ehealth.sundhed.dk/cs/clinicalimpression-finding-codesExample value - Under construction

Example value - Under construction

  NPU03011urn:oid:1.2.208.176.2.1O2 sat.;Hb(aB)

Hb(Fe; O2-bind.; aB)—Oxygen(O2); mætn. = ?

  NPU21692urn:oid:1.2.208.176.2.1Puls;Hjerte

Hjerte—Systole; frekv. = ? × 1/min

  NPU03804urn:oid:1.2.208.176.2.1Legeme vægt; Pt

Pt—Legeme; masse = ? kg

  NPU27281urn:oid:1.2.208.176.2.1Pt—Legeme; massekoefficient(masse/kvadreret højde) = ? kg/m²

Pt—Legeme; massekoefficient(masse/kvadreret højde) = ? kg/m²

  NPU03794urn:oid:1.2.208.176.2.1Pt—Legeme; højde = ? m

Pt—Legeme; højde = ? m

  MCS88015urn:oid:1.2.208.184.100.8FEV1;Lunge

Lunge—Lungefunktionsundersøgelse FEV1; vol. = ? L

  MCS88016urn:oid:1.2.208.184.100.8FVC;Lunge

Lunge—Lungefunktionsundersøgelse vitalkapasitet FVC; vol. = ? L

  MCS88017urn:oid:1.2.208.184.100.8FEV1/FVC;Lunge

Lunge—FEV1/FVC; ratio = ?

  MCS88019urn:oid:1.2.208.184.100.8Blodtryk hjemme systolisk;Arm

Arm—Blodtryk(systolisk) hjemme; tryk = ? mmHg

  MCS88020urn:oid:1.2.208.184.100.8Blodtryk hjemme diastolisk;Arm

Arm—Blodtryk(diastolisk) hjemme; tryk = ? mmHg

  MCS88021urn:oid:1.2.208.184.100.8MRC skala;Pt(KOL)

Pt(KOL) —MRC skala; arb.antal(værdi 1-5) = ?

  MCS88023urn:oid:1.2.208.184.100.8FEV1 af forventet værdi;Pt(KOL)

Pt(KOL) - FEV1 i % af den forventede værdi (efter højde,alder og køn); ratio = ?

  MCS88050urn:oid:1.2.208.184.100.8Rejse sætte sig testen;Pt

Pt—Rejse sætte sig testen; antal (værdi 0-50) = × 1/ 30 sek

  MCS88137urn:oid:1.2.208.184.100.8CAT score;Pt

Pt—CORD Assessment Test (CAT) score; antal(værdi 0-40) = ?

  ZZ3170urn:oid:1.2.208.176.2.4Hjemmeblodtryksmåling udført af patienten
  281300000http://snomed.info/sctBelow reference range
  281302008http://snomed.info/sctAbove reference range
  281301001http://snomed.info/sctWithin reference range
  394844007http://snomed.info/sctOutside reference range
  442686002http://snomed.info/sctMeasurement finding below reference range
  442756004http://snomed.info/sctMeasurement finding above reference range
  442082004http://snomed.info/sctMeasurement finding within reference range
  442096005http://snomed.info/sctMeasurement finding outside reference range
  449171008http://snomed.info/sctOxygen saturation below reference range
  448225001http://snomed.info/sctOxygen saturation within reference range

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code