eHealth Infrastructure (v2020.4)

fetch-patient-devices

OPERATION: fetch-patient-devices

The official URL for this operation definition is:

http://ehealth.sundhed.dk/fhir/OperationDefinition/-s-fetch-patient-devices

Report Contents

This report contains Device information for each EpisodeOfCare:

  • Device
  • DeviceUseStatement
  • DeviceMetrics

Grouping

This report is grouped by EpsiodeOfCare. Each group is returned in a separate JSon file.

Parameters

  • organization: Filter on EpisodeOfCare.managingOrganization match
  • period: Filter on DeviceUseStatement.whenUsed overlap

Output

Output can be found in Binary.content. This is a Base64 encoded .zip file containing JSon files corresponding to the report groups.

Example output

All returned objects are Fhir resources. See the implementation guide for details

{
    'EHealthEpisodeOfCare': {
        'resourceType': 'EpisodeOfCare',
        'id': 'F417C17F9FDE24C9090BD629C8EE1697',
        'meta': {
            'versionId': '1',
            'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-episodeofcare']
        },
        'extension': [{
                'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-episodeofcare-caremanagerOrganization',
                'valueReference': {
                    'reference': 'https://organization.local.ehealth.sundhed.dk/fhir/Organization/313D8B0E0AC8EA8169D1DA45ECEEACB9'
                }
            }
        ],
        'status': 'active',
        'diagnosis': [{
                'condition': {
                    'reference': 'https://careplan.local.ehealth.sundhed.dk/fhir/Condition/9A7FCD55CA3031585A8F1690DB1D8034'
                },
                'rank': 1
            }
        ],
        'patient': {
            'reference': 'https://patient.local.ehealth.sundhed.dk/fhir/Patient/A1D94F323D8EF09E5D913D9522FD83C4'
        },
        'managingOrganization': {
            'reference': 'https://organization.local.ehealth.sundhed.dk/fhir/Organization/8DC75F2B12BCC832F92CC065C3D0B451'
        },
        'period': {
            'start': '1970-01-01T01:00:01+01:00',
            'end': '1970-01-01T01:01:40+01:00'
        }
    },
    'EHealthDeviceUseStatement': [{
            'resourceType': 'DeviceUseStatement',
            'id': '9541E8EAEAD24376F208D5CD8A4D25F5',
            'meta': {
                'versionId': '1',
                'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement']
            },
            'extension': [{
                    'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context',
                    'valueReference': {
                        'reference': 'https://careplan.local.ehealth.sundhed.dk/fhir/CarePlan/23D34B29DD02EB232B6575537FE8ADC5'
                    }
                }
            ],
            'status': 'active',
            'subject': {
                'reference': 'https://patient.local.ehealth.sundhed.dk/fhir/Patient/AC38B1F6391F256002E5A7BE69CB2586'
            },
            'device': {
                'reference': 'https://device.local.ehealth.sundhed.dk/fhir/Device/08D51B81A7FE5B480278150A94D4048A'
            }
        }
    ],
    'EHealthDevice': [{
            'resourceType': 'Device',
            'id': '08D51B81A7FE5B480278150A94D4048A',
            'meta': {
                'versionId': '1',
                'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device']
            },
            'extension': [{
                    'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-privatelyOwned',
                    'valueBoolean': true
                }
            ],
            'status': 'active'
        }
    ],
    'EHealthDeviceMetric': [{
            'resourceType': 'DeviceMetric',
            'id': '7EA21ACD27EE012439F1440574A6BB21',
            'meta': {
                'versionId': '1',
                'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric']
            },
            'extension': [{
                    'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-qualities',
                    'extension': [{
                            'url': 'category',
                            'valueCodeableConcept': {
                                'coding': [{
                                        'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',
                                        'code': 'initial'
                                    }
                                ]
                            }
                        }, {
                            'url': 'value',
                            'valueInteger': 5
                        }
                    ]
                }, {
                    'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities',
                    'extension': [{
                            'url': 'category',
                            'valueCodeableConcept': {
                                'coding': [{
                                        'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',
                                        'code': 'initial'
                                    }
                                ]
                            }
                        }, {
                            'url': 'value',
                            'valueInteger': 10
                        }
                    ]
                }, {
                    'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities',
                    'extension': [{
                            'url': 'category',
                            'valueCodeableConcept': {
                                'coding': [{
                                        'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',
                                        'code': 'initial'
                                    }
                                ]
                            }
                        }, {
                            'url': 'value',
                            'valueInteger': 12
                        }
                    ]
                }, {
                    'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities',
                    'extension': [{
                            'url': 'category',
                            'valueCodeableConcept': {
                                'coding': [{
                                        'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',
                                        'code': 'initial'
                                    }
                                ]
                            }
                        }, {
                            'url': 'value',
                            'valueInteger': 14
                        }
                    ]
                }
            ],
            'identifier': {
                'value': 'Foo'
            },
            'type': {
                'text': 'code'
            },
            'source': {
                'reference': 'https://device.local.ehealth.sundhed.dk/fhir/Device/08D51B81A7FE5B480278150A94D4048A'
            },
            'category': 'calculation'
        }
    ]
}

URL: [base]/$fetch-patient-devices

Parameters

UseNameCardinalityTypeBindingDocumentation
INanonymization1..1string
INorganization0..1Reference
INperiod0..1Period
INdevicetype0..1Coding
OUTreturn0..1Binary